![SCHUNK PRG 100 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/schunk/prg-100/prg-100_assembly-and-operating-manual_1215996030.webp)
Assembly
30
08.00 | PRG | Assembly and Operating Manual | en | 389325
4.3.5 Magnetic switch MMS 22 / RMS 22
NOTE
The sensor can be used only for sizes 26–64
CAUTION
Material damage due to an incorrect tightening torque!
If the threaded pin is tightened with an incorrect tightening
torque, the product may be damaged.
•
Observe a maximum tightening torque of 10 Ncm for the set-
screws.
The RMS sensors have a larger hysteresis than the MMS sensors.
This means that short gripper strokes may not be able to be
monitored with the RMS sensors.
Positioning the
magnetic switch
Positioning of the magnetic switches