Maintenance
48
10.00 | PGN-plus-P | Assembly- and Operating Manual | en | 389753
7 Maintenance
7.1 Notes
Original spare parts
Use only original spare parts of SCHUNK when replacing spare and
wear parts.
Exchange of housing and base jaws
The base jaws and the guidance in the housing are matched. To
exchange these parts, send the product with a repair order to
SCHUNK or order the housing with the base jaws as a set.
7.2 Maintenance intervals
If products are used at room temperature and the ambient and
operating conditions are adhered to, these variants are
maintenance-free,
Products for special ambient conditions are excluded, e.g. higher
temperatures, dirty environment.
If products are not used at room temperature or in special
ambient conditions, the following maintenance intervals apply
Interval (million
cycles)
Maintenance work
10
Clean the product dry without a degreasing
agent, check for damage and wear.
10
10
Treat all grease areas with lubricant,
Lubricants/Lubrication points (basic
lubrication)
49],
For extreme ambient and application conditions, shortened
maintenance cycles can ensure the lifespan is maintained.
CAUTION
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
•
Reduce the lubricant intervals accordingly.