![SCHUNK PGN-plus-P Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/schunk/pgn-plus-p/pgn-plus-p_assembly-and-operating-manual_1215988050.webp)
Maintenance
50
10.00 | PGN-plus-P | Assembly- and Operating Manual | en | 389753
7.5 Replace seals
7.5.1 Replace seal (variant without gripping force maintenance)
Ø
Remove all compressed air lines,
23].
Ø
Remove product from the system/machine.
Ø
Variant Dust-tight (SD):
Ø
Remove the cover (10).
Ø
Mark the installation position of the base jaws (3) on the
housing (2).
Ø
Remove the screws and the cover (4).
Ø
Unscrew screw (6) and take cylinder piston (8) out of the
housing (2).
Ø
Push the wedge hook (1) out of the housing (2).
Ø
Take base jaws (3) out of the housing (2).
Ø
Remove old seals (9, 5 and 7).
Ø
Clean guiding areas.
Ø
Mount new seals (9 and 7) from the seal kit.
Ø
Re-lubricating guiding areas
Ø
Insert base jaws (3) into the housing (2).
IMPORTANT! Observe
installation position of the base jaws (3) in the housing (2).
Ø
Insert wedge hook (1) into the housing (2).
Ø
Insert cylinder piston (8) into the housing (2) and tighten screw
(6). Secure the screw with medium-strength threadlocker.
Tightening torque:
Ø
Insert flat gasket (5).
Ø
Fasten the cover (4) with the screws.
Tightening torque:
Содержание PGN-plus-P
Страница 1: ...Translation of the original manual Assembly and Operating Manual PGN plus P 2 Finger Parallel Gripper ...
Страница 57: ...Maintenance 10 00 PGN plus P Assembly and Operating Manual en 389753 57 PGN plus P 300 380 standard ...
Страница 60: ...Maintenance 60 10 00 PGN plus P Assembly and Operating Manual en 389753 Variant dust tight SD ...