Assembly
10.00 | PGN-plus-P | Assembly- and Operating Manual | en | 389753
35
5.4.8 Mounting programmable MMS 22-P 22 magnetic switch
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
NOTE
If there is no T-nut available, slide the sensor according to
dimension I1 into the groove (2),
Setting dimensions for magnetic
Ø
Turn the sensor (1) into the groove (2).
OR: Slide the sensor (1) into the groove (2) until the sensor (1)
stops at the T-nut (3).
Ø
Secure the sensor (1) using the set-screw (4).
Tightening torque: 10 Ncm
Ø
Adjust sensor (1), see sensor assembly and operating manual.