7.3 Lubricants/Lubrication points (basic lubrication)
SCHUNK recommends the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubricant point
Lubricant
Metallic sliding surfaces
microGLEIT GP 360
All seals
Renolit HLT 2
Cylinder surfaces
Renolit HLT 2
7.4 Lubricate product
WARNING
Risk of injury due to moving parts!
When moving the gripper fingers, body parts may get squashed/
hit causing severe injuries.
•
Do not interfere with moving parts during operation.
•
Observe position and direction of movement of the gripper
fingers.
Ø
Remove set-screw on an air purge connection (1).
Ø
Screw in lubrication nipple.
Ø
Apply a layer of grease to metallic sliding surfaces of the gripper
using the lubrication nipple,
Lubricants/Lubrication points (basic
49].
✓
While lubricating, completely open and close the gripper
alternately.
Ø
Unscrew the lubrication nipple.
Ø
Screw set-screws into both air purge connections (1).