Trouble shooting
46
02.00|NSL3 turn 450-3, 450-3-Z, 570-5, 570-5-Z |en
Trouble shooting
The clamping area fails to unlock properly, or at all
Possible cause
Remedial measures
Operating pressure below 5 bar
Increase operating pressure
The clamping station was not operated
with oiled compressed air
Air must be supplied via a separate
maintenance unit with an oiler
Defective air connections
Check air supply
Excessive tensile load on clamping slides Reduce load
The turbo connection is still pressurized
Ventilate turbo connection
Leaky air supply or air connection
Check connections and seals
Pressure indicator for monitoring turbo not working correctly
Possible cause
Remedial measures
Leaky pressure indicator or air supply
Check connections and seals
Deterioration in centering accuracy
Possible cause
Remedial measures
The taper surfaces on the versatile
centering taper or the centering sleeve
are damaged or worn
Replace damaged parts with SCHUNK original
spare parts
The clamping pins are not arranged
correctly on the clamping pallet
Check arrangement
The clamping setup does not correspond
to the required balancing grade G 6.3
Balance according to the required balancing
grade
7