
Troubleshooting
16
01.03|MV 15 - 30|en
Troubleshooting
Valve does not open when switched on
Possible cause
Solution(s)
Compressed air supply is too low, micro
valve only opens with pressure support
depending on the design
Increase the supply pressure to the mini-
mum operating pressure,
Micro valve not screwed in as far as possible Check the thread of the swivel fitting,
Screw in the valve cartridge completely.
Incorrect polarity (only possible with micro
valve with a valve cover and recovery diode)
Make the correct connection assignment,
Supply voltage too low
Check the supply voltage, see catalog data
sheet.
Valve is "not tight" when switched off
Possible cause
Solution(s)
Connection with screws or valve cartridge
not tightened correctly
Tighten connections with screws of the indi-
vidual components,
Foreign object on the sealing face or sealing
contour
Clean the sealing face and sealing contour,
Observe the incompatibility of the sealing
material,
Supply pressure too high
Reduce the supply pressure to the maximum
operating pressure,
7
7.1
7.2
Содержание MV 15
Страница 18: ...Notes 18 01 03 MV 15 30 en Notes...
Страница 19: ...Notes 01 03 MV 15 30 en 19 Notes...
Страница 20: ...20 01 03 MV 15 30 en...