Assembly and installation
01.03|MV 15 - 30|en
11
Electrical connection
NOTICE
Damage to the cable is possible.
The bending radius of the cable is not allowed to be less than the
minimum amount:
•
Static:
10 times the cable diameter.
•
Dynamic:
15 times the cable diameter, suitable for cable
tracks.
NOTE
Route and secure the connection cable so there are no tensile and
twisting forces on the valve cover. Tensile and twisting forces can
cause the screw cap to come loose and lead to contact problems.
PIN allocation M8 plug and cable color table extension
PIN
Cable color
Assignment
1
Brown
n.c.
3
Blue
GND
4
Black
Control voltage,
+24 VDC
Screw cap with LED:
If the connection cable of the micro valve has been connected
correctly to the electrical power supply, the LED in the screw cap
will light up when the 24 VDC voltage is applied.