Assembly
24
05.00|21151452 KSP plus-IN, KSP-LH plus-IN, KSP plus-IN2, KSP-LH plus-IN2 |en
• Position the sensor so that the signal LED on the sensor head is
clearly visible (with cover, LED is not visible).
• Prevent the proximity switch from coming into contact with
hard objects or with chemicals; in particular, nitric, chromic or
sulfuric acid.
Proximity switches are electronic components which can react
sensitively to high-frequency interference or electromagnetic
fields.
• Check that the cable is correctly connected and installed. There
must be sufficient distance between the switches and sources
of interference and their supply cables.
• Parallel switching of multiple sensor outputs of the same design
(npn, pnp) is permissible, though this does not increase the
permissible load current.
• Please note that the leakage current of the individual sensors is
accumulative (by about 2 mA).