Commissioning
48
01.00|IndraDrive CS |en
Testing measuring system
1 In the tree view of the project Explorer, select folder
<IndraDrive> → <Application>.
2 Right click <Application> and then select <Diagnosis> →
<Status> from the resulting context menu. The dialog box for
the <Status> folder appears.
Fig. 15
checking status
1 Move the carriage by hand. There should be no leaps in the
display "position".
2 Apply a Scale (about 10 cm) on the guide blade carriage and
move carrier along the scale.
3 Compare the measured travel distance with the display of the
actual position.
3.2.4