28
11.00 | EZN | Assembly and Operating Manual | en | 389068
5.2 Connections
5.2.1 Mechanical connection
Evenness of the
mounting surface
The values apply to the whole mounting surface to which the
product is mounted.
Requirements for evenness of the mounting surface (Dimensions in mm)
Edge length
Permissible unevenness
< 100
< 0.02
> 100
< 0.05
Choose the installation position so that connection cables are not
damaged or cannot wrap around the product when swiveling.
Preconditions for installing the connection cables:
• The cables are without tensile and torsion loads. Use cable
guide chains.
• The minimum bending radius (7.5 times the cable diameter) is
observed.
Assembly of the top jaws