Technical data
11.00 | EZN | Assembly and Operating Manual | en | 389068
23
3.4 SCHUNK power and sensor cable
Cable type
Power
Transducer
Number of wires/cross-section
4 x 0.75 mm²
+
2 x 0.25 mm²
8 x 0.25 mm²
Max. voltage [V]
600
24
Shielded
yes
yes
Shield around individual wire
strands
no
yes
Twisted
no
yes
Temperature application range [°C] +5 to +55
+5 to +55
Max. cable length [m]
20
20
Max. conductor resistance
0.25 mm
2
0.75 mm
2
78 Ohm/km
26 Ohm/km
78 Ohm/km
-
Cable type
Power
Transducer
Cable track
Bending radius [x times the cable diameter]
once
several times
permanently (cable track)
3 x D
7.5 x D
10 x D
Cable type
Power
Transducer
Torsion
Bending radius [x times the cable diameter]
once
several times
permanently (torsion)
5 x D
8.5 x D
12 x D
Torsion range
±180 °/m
The catalog data sheet contains further information on the cable
as well as a drawing of it.