Assembly and settings
02.02|AGE-F-XY 31-80|en
17
Position of the position numbers
(
10, Page 24)
:
1 Remove the setscrews (50).
2 Remove the spring sleeve (4) and take out the springs (15).
As standard, three springs are available for each size. Special
springs on request.
The new springs are assembled in the reverse order.
Pay attention to correct lubricating.
(
9.2, Page 21)
Removing and replacing return springs for units built
beginning in June 2016
The unit comprises 4 compression springs for the return position
function.
As of June 2016, the unit's spring force values can no longer be ad-
justed.
Replacing the springs
Position of the position numbers
(
10, Page 24)
:
1 Remove the setscrews (50).
2 Remove the spring sleeve (4) and take out the springs (15).
As standard, three springs are available for each size. Special
springs on request.
The new springs are assembled in reverse order.
Pay attention to correct lubricating.
(
9.2, Page 21)
Removing / Replacing
7.5
Removing / Replacing