1. Note the polarity of the battery posts

by checking the identification marks
on the battery: POSITIVE (POS, P or
+) and NEGATIVE (NEG, N or -). The
positive post is usually larger than
the negative post.

2. Attach at least a 24-inch-long, 6-

gauge (AWG), insulated battery
cable to NEGATIVE (NEG, N or -)
battery post. Rock and twist the
clamp back and forth to be sure a
solid electrical connection is made.

3. Connect the red (POSITIVE) output

clamp to the POSITIVE battery post.
Rock and twist the clamp back and
forth to be sure a solid electrical
connection is made.

4. Position yourself as far away from

the battery as possible, and then
connect the black (NEGATIVE)
output clamp to the free end of the
cable.

5. Plug the power cord into an AC

outlet. The charger will be set to the
default state of 2A charge rate and
REGULAR battery type (tester).

6. Press the appropriate control buttons

to select the desired charge rate and
battery type. Within a few seconds,
the CHARGING (yellow) LED should
light and the charging process should
start. If the CHECK (red) LED is on,
check for correct cable connections.

POSITIVE

NEGATIVE

BATTERY CHARGER

BATTERY

24", 6 GAUGE
CABLE

POWER
CORD

TO

GROUNDED

POWER

OUTLET

CHARGING BATTERY REMOVED
FROM THE VEHICLE:

7. To disconnect the Charger, unplug

its power cord before attempting to
disconnect the charger clamps. Then,
standing away from the battery,
remove the output clamp from the
NEGATIVE battery post. Finally,
remove the output clamp from the
POSITIVE battery post.

8. Clean and store the charger in a dry

location.

USING ENGINE START

Your battery charger can be used to
jump start your car if the battery is low.
Follow these instructions on how to use
the ENGINE START feature.

IMPORTANT: 

Follow all safety instruc-

tions and precautions when charging
your battery. Wear complete eye
protection and clothing protection.
Charge your battery in a well-ventilated
area.

IMPORTANT: 

Using the ENGINE

START feature WITHOUT a battery
installed in the vehicle could cause
damage to the vehicle’s electrical
system.

1. With the charger plugged in and

connected to the battery of the
vehicle, set the CHARGE RATE to
60A START. Only the 60A START
and CHARGING LEDs (both yellow)
should be lit.

2. Crank the engine for no more than 8

seconds. If engine does not start,
wait 2 minutes before cranking again.

3. After the engine starts, unplug the

power cord before disconnecting the
output clamps from the battery.

4. Clean and store the charger in a dry

location.

Содержание SpeedCharge 6000A

Страница 1: ...99000399 0104 OWNER S MANUAL Schumacher Electric Corporation Mount Prospect IL 60056 U S A Model 6000A For 12 Volt Batteries SpeedCharge computer smart 30a m p R A P I D C H A R G E 60a m p E N G I N...

Страница 2: ...nt does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the interfer ence by one or mor...

Страница 3: ...TE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY To reduc...

Страница 4: ...ave plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touchin...

Страница 5: ...e a 12 volt lead acid battery Determine voltage of battery by referring to vehicle owner s manual Charge battery initially at charger s lowest rate Clean the battery terminals Be care ful to keep corr...

Страница 6: ...s the CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the Charger unplug its power cord before att...

Страница 7: ...4 6 GAUGE CABLE POWER CORD TO GROUNDED POWER OUTLET CHARGING BATTERY REMOVED FROM THE VEHICLE 7 To disconnect the Charger unplug its power cord before attempting to disconnect the charger clamps Then...

Страница 8: ...an engine with a weak or 6000A CONTROL PANEL run down battery Always use in combination with a battery BATTERY TYPE SWITCH Use this switch button to set the type of battery to be charged to one of the...

Страница 9: ...nator O O 0 199 2 Amp charge with battery detected O O xx or xx xV 10 Amp charge with battery detected O YEL xx or xx xV 30 Amp charge activated O ORG xx or xx xV Charge complete Maintain Mode started...

Страница 10: ...n minutes after the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTINGAFTERCHARGING After the unit has been changed from tester to cha...

Страница 11: ...HARGING yellow LED does not light in the alternator test mode The CHECK red LED lights if the voltage is much higher or lower than normally desired When the tester display mode is set to voltage none...

Страница 12: ...harger is very simple First connect the battery and AC power following the precautions listed under OPERATING INSTRUC TIONS Then select the appropriate BATTERY TYPE and CHARGE RATE for your battery Th...

Страница 13: ...charging has started by pressing the CHARGE RATE or BATTERY TYPE button the charging process will be restarted The voltage displayed during charging is the charging voltage and usually will be higher...

Страница 14: ...d eventually reduces the charge rate in a controlled manner After the charging process has started the digital display can be used to determine charging progress by selecting the BATTERY mode There ar...

Страница 15: ...k of battery clip Select the batteries requiring more desired charge rate and power than a 30 10 Amp battery type again if charger can deliver within necessary 24 hours The battery may also be faulty...