Schumacher SpeedCharge 6000A Скачать руководство пользователя страница 4

4

Never

 place charger directly above

battery being charged. The gases from
the battery will corrode and damage the
charger.

Never 

touch the battery clamps together

when the charger is on. You could
cause a spark.

Never 

operate charger if it has received

a hard blow, been dropped, or otherwise
damaged. Take it to a qualified profes-
sional for inspection and repair.

Be sure

 to position the charger power

cord to prevent it from being stepped
on, tripped over, or damaged.

Never

 pull out the plug by the cord

when unplugging the SpeedCharge.
Pulling on the cord may cause damage
to the cord or the plug.

Do not

 operate the SpeedCharge if it

has a damaged power cord or plug.
Have the cord replaced.

PERSONAL SAFETY PRECAUTIONS

Wear complete eye and clothing
protection 

when working with lead-

acid batteries.

Make sure 

that someone is within

range of your voice to come to your
aid if needed while you work with or
are near a lead-acid battery.

Have plenty of fresh water and
soap 

nearby for use in case battery

acid contacts your eyes, skin, or
clothing. If this happens, wash
immediately with soap and water.
Then get medical attention.

Avoid touching your eyes 

while

working with a battery. Acid particles
(corrosion) may get into your eyes. If
this occurs, flush eyes immediately
with running cold water for at least 10
minutes. Then immediately get
medical attention.

Never

 charge a frozen battery.

Remove all personal metal items

from your body such as rings,
bracelets, necklaces and watches,
while working with a lead-acid battery.
A battery can produce a short circuit
current high enough to weld a ring (or
the like) to metal, causing a severe
burn.

Take care 

not to drop any metal tool

or metal object onto the battery. This
may spark or short circuit the battery
or another electrical device that may
cause an explosion.

Always 

operate the battery charger in

an open, well-ventilated area.

Never 

smoke or allow a spark or

flame in the vicinity of the battery or
engine. Batteries generate explosive
gases.

Neutralize 

any acid spills thoroughly

with baking soda before attempting to
clean up.

Содержание SpeedCharge 6000A

Страница 1: ...99000399 0104 OWNER S MANUAL Schumacher Electric Corporation Mount Prospect IL 60056 U S A Model 6000A For 12 Volt Batteries SpeedCharge computer smart 30a m p R A P I D C H A R G E 60a m p E N G I N...

Страница 2: ...nt does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the interfer ence by one or mor...

Страница 3: ...TE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY To reduc...

Страница 4: ...ave plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touchin...

Страница 5: ...e a 12 volt lead acid battery Determine voltage of battery by referring to vehicle owner s manual Charge battery initially at charger s lowest rate Clean the battery terminals Be care ful to keep corr...

Страница 6: ...s the CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the Charger unplug its power cord before att...

Страница 7: ...4 6 GAUGE CABLE POWER CORD TO GROUNDED POWER OUTLET CHARGING BATTERY REMOVED FROM THE VEHICLE 7 To disconnect the Charger unplug its power cord before attempting to disconnect the charger clamps Then...

Страница 8: ...an engine with a weak or 6000A CONTROL PANEL run down battery Always use in combination with a battery BATTERY TYPE SWITCH Use this switch button to set the type of battery to be charged to one of the...

Страница 9: ...nator O O 0 199 2 Amp charge with battery detected O O xx or xx xV 10 Amp charge with battery detected O YEL xx or xx xV 30 Amp charge activated O ORG xx or xx xV Charge complete Maintain Mode started...

Страница 10: ...n minutes after the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTINGAFTERCHARGING After the unit has been changed from tester to cha...

Страница 11: ...HARGING yellow LED does not light in the alternator test mode The CHECK red LED lights if the voltage is much higher or lower than normally desired When the tester display mode is set to voltage none...

Страница 12: ...harger is very simple First connect the battery and AC power following the precautions listed under OPERATING INSTRUC TIONS Then select the appropriate BATTERY TYPE and CHARGE RATE for your battery Th...

Страница 13: ...charging has started by pressing the CHARGE RATE or BATTERY TYPE button the charging process will be restarted The voltage displayed during charging is the charging voltage and usually will be higher...

Страница 14: ...d eventually reduces the charge rate in a controlled manner After the charging process has started the digital display can be used to determine charging progress by selecting the BATTERY mode There ar...

Страница 15: ...k of battery clip Select the batteries requiring more desired charge rate and power than a 30 10 Amp battery type again if charger can deliver within necessary 24 hours The battery may also be faulty...

Страница 16: ...turer or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages...

Отзывы: