Schumacher SpeedCharge 6000A Скачать руководство пользователя страница 10

10

USING THE BUILT-IN BATTERY TESTER

OVERVIEW

The SpeedCharge has a built-in battery
tester that displays either an accurate
battery voltage or an estimate of the
battery’s relative charge based on the
battery voltage and the Battery Council
International scale.

TESTING SEQUENCE

There are four basic steps required to
use the 6000A as a battery tester.
1. Connect the SpeedCharge battery

clamps to the battery. Be sure to follow
all of the precautions listed under
“OPERATING INSTRUCTIONS”.

2. Connect the SpeedCharge power cord

to a 120 VAC outlet. Again, be sure to
follow all of the precautions listed under
“OPERATING INSTRUCTIONS”.

3. If necessary, press the Battery Type

button until the correct type is indi-
cated.

4. Read the voltage on the digital LED or

press the display mode button to set
the tester to “Battery %” and read the
battery percent.

TESTER AND CHARGER

When first turned on, the 6000A oper-
ates only as a tester, not as a charger.
To continue to use it as only a tester,
avoid pressing the CHARGE RATE
switch button. Selecting a charge rate
activates the battery charger and
deactivates the tester.

POWER-UP IDLE TIME LIMIT

If no switch button is pressed within ten
minutes after the unit is first powered
up, the unit will automatically switch
from tester to charger, if a battery is
connected. In that case, the unit will be
set for the 2A charge rate and REGU-
LAR battery type.

TESTER WITHOUT TIME LIMIT

If either the DISPLAY MODE or BAT-
TERY TYPE button is pressed within the
first ten minutes after the unit is
powered up, the unit will remain a tester
(not a charger) indefinitely, unless a
charge rate is selected.

TESTING AFTER CHARGING

After the unit has been changed from
tester to charger (by selecting a charge
rate), it remains a charger as long as it
has power. Disconnect and reconnect
the power to change the unit back to a
tester.

TESTER STATUS LEDs

When the 6000A is operating as a
battery tester, the status LEDs light
under the following conditions.
• The CHARGED (green) LED will light

if a charged battery is tested.

• The CHARGING (yellow) LED does

not light in the battery test mode.

• The CHECK (red) LED lights unless a

properly connected battery is de-
tected.

• When the tester display mode is set

to voltage, none of the Status LEDs
light (it could be testing a battery or
an alternator).

INITIAL PERCENT CALCULATION

When a battery % is calculated for the
first time after connecting a battery, the
digital LED will show two dashes (“--”)
for a period as long as several seconds
while the tester analyzes the battery.

NOTES FOR TESTING BATTERY %

A recently charged battery could have a
temporarily high voltage due to what is
known as “surface charge”. The voltage
of such a battery will gradually drop
during the period immediately after the
charging system is disengaged.
Consequently, the tester could display
inconsistent values for such a battery.
For a more accurate reading, the
surface charge should be removed by
temporarily creating a load on the
battery, such as by turning on lights or
other accessories.

The battery % ranges from 0 to 100.

The battery tester is only designed to
test batteries. Testing a device with a
rapidly changing voltage could yield
unexpected or inaccurate results.

Содержание SpeedCharge 6000A

Страница 1: ...99000399 0104 OWNER S MANUAL Schumacher Electric Corporation Mount Prospect IL 60056 U S A Model 6000A For 12 Volt Batteries SpeedCharge computer smart 30a m p R A P I D C H A R G E 60a m p E N G I N...

Страница 2: ...nt does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the interfer ence by one or mor...

Страница 3: ...TE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY To reduc...

Страница 4: ...ave plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touchin...

Страница 5: ...e a 12 volt lead acid battery Determine voltage of battery by referring to vehicle owner s manual Charge battery initially at charger s lowest rate Clean the battery terminals Be care ful to keep corr...

Страница 6: ...s the CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the Charger unplug its power cord before att...

Страница 7: ...4 6 GAUGE CABLE POWER CORD TO GROUNDED POWER OUTLET CHARGING BATTERY REMOVED FROM THE VEHICLE 7 To disconnect the Charger unplug its power cord before attempting to disconnect the charger clamps Then...

Страница 8: ...an engine with a weak or 6000A CONTROL PANEL run down battery Always use in combination with a battery BATTERY TYPE SWITCH Use this switch button to set the type of battery to be charged to one of the...

Страница 9: ...nator O O 0 199 2 Amp charge with battery detected O O xx or xx xV 10 Amp charge with battery detected O YEL xx or xx xV 30 Amp charge activated O ORG xx or xx xV Charge complete Maintain Mode started...

Страница 10: ...n minutes after the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTINGAFTERCHARGING After the unit has been changed from tester to cha...

Страница 11: ...HARGING yellow LED does not light in the alternator test mode The CHECK red LED lights if the voltage is much higher or lower than normally desired When the tester display mode is set to voltage none...

Страница 12: ...harger is very simple First connect the battery and AC power following the precautions listed under OPERATING INSTRUC TIONS Then select the appropriate BATTERY TYPE and CHARGE RATE for your battery Th...

Страница 13: ...charging has started by pressing the CHARGE RATE or BATTERY TYPE button the charging process will be restarted The voltage displayed during charging is the charging voltage and usually will be higher...

Страница 14: ...d eventually reduces the charge rate in a controlled manner After the charging process has started the digital display can be used to determine charging progress by selecting the BATTERY mode There ar...

Страница 15: ...k of battery clip Select the batteries requiring more desired charge rate and power than a 30 10 Amp battery type again if charger can deliver within necessary 24 hours The battery may also be faulty...

Страница 16: ...turer or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages...

Отзывы: