Schumacher SpeedCharge 6000A Скачать руководство пользователя страница 11

11

The SpeedCharge has a built-in
alternator tester that displays either an
accurate alternator voltage or an
estimate of the alternator’s relative
output compared to normal alternators.
The Alternator % values displayed
should be taken as general reference,
not precise diagnosis. The alternator
tester functions the same as the battery
tester (see previous section of this
manual for details) with a few differences.

TESTING SEQUENCE

There are three basic steps required to
use the 6000A as an alternator tester.

1. Connect the SpeedCharge battery

clamps to the battery or charging
system. Be sure to follow all of the
precautions listed under “OPERAT-
ING INSTRUCTIONS”.

2. Connect the SpeedCharge power

cord to a 120 VAC outlet. Again, be
sure to follow all of the precautions
listed under “OPERATING INSTRUC-
TIONS”.

3. Start the vehicle and turn on the

vehicle’s headlights. Read the voltage
on the digital LED or press the

USING THE BUILT-IN ALTERNATOR TESTER

display mode button to set the tester
to “Alternator %” and read the
alternator percent.

TESTER STATUS LEDs

When the 6000A is operating as an
alternator tester, the status LEDs light
under the following conditions.

• The CHARGED (green) LED will light

if the output of the charging system is
at the normally desired level.

• The CHARGING (yellow) LED does

not light in the alternator test mode.

• The CHECK (red) LED lights if the

voltage is much higher or lower than
normally desired.

• When the tester display mode is set

to voltage, none of the status LEDs
light (it could be testing a battery or
an alternator).

ALTERNATOR TESTING NOTES

• The alternator percent display can

range from 0 to 199.

• The display mode cannot be set to

“Alternator %” during charging.

OVERVIEW

The 6000A has an engine start function
that can be used to jump start your
vehicle if the battery is low by providing
60 amps of current to assist engine
cranking.

STARTING SEQUENCE

There are a few basic steps involved
when using the engine start function.

1. Connect the SpeedCharge battery

clamps to the battery or charging
system. Be sure to follow all of the
precautions listed under “OPERAT-
ING INSTRUCTIONS”.

2. Connect the SpeedCharge power

cord to a 120 VAC outlet. Again, be
sure to follow all of the precautions

USING YOUR ENGINE STARTER

listed under “OPERATING INSTRUC-
TIONS”.

3. Press the CHARGE RATE button

until the 60 START indicator is lit.

4. Crank the engine until it starts or 8

seconds passes.

5. If the engine did not start, wait for the

SpeedCharge to cool then repeat
step 4.

During the starting sequence listed
above, the charger is set to one of three
states.

1.

Wait for cranking

 - The charger

waits until the engine is actually
being cranked before delivering 60
amps for engine start. The charger
delivers charge at a rate of 10 amps

Содержание SpeedCharge 6000A

Страница 1: ...99000399 0104 OWNER S MANUAL Schumacher Electric Corporation Mount Prospect IL 60056 U S A Model 6000A For 12 Volt Batteries SpeedCharge computer smart 30a m p R A P I D C H A R G E 60a m p E N G I N...

Страница 2: ...nt does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the interfer ence by one or mor...

Страница 3: ...TE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY To reduc...

Страница 4: ...ave plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touchin...

Страница 5: ...e a 12 volt lead acid battery Determine voltage of battery by referring to vehicle owner s manual Charge battery initially at charger s lowest rate Clean the battery terminals Be care ful to keep corr...

Страница 6: ...s the CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the Charger unplug its power cord before att...

Страница 7: ...4 6 GAUGE CABLE POWER CORD TO GROUNDED POWER OUTLET CHARGING BATTERY REMOVED FROM THE VEHICLE 7 To disconnect the Charger unplug its power cord before attempting to disconnect the charger clamps Then...

Страница 8: ...an engine with a weak or 6000A CONTROL PANEL run down battery Always use in combination with a battery BATTERY TYPE SWITCH Use this switch button to set the type of battery to be charged to one of the...

Страница 9: ...nator O O 0 199 2 Amp charge with battery detected O O xx or xx xV 10 Amp charge with battery detected O YEL xx or xx xV 30 Amp charge activated O ORG xx or xx xV Charge complete Maintain Mode started...

Страница 10: ...n minutes after the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTINGAFTERCHARGING After the unit has been changed from tester to cha...

Страница 11: ...HARGING yellow LED does not light in the alternator test mode The CHECK red LED lights if the voltage is much higher or lower than normally desired When the tester display mode is set to voltage none...

Страница 12: ...harger is very simple First connect the battery and AC power following the precautions listed under OPERATING INSTRUC TIONS Then select the appropriate BATTERY TYPE and CHARGE RATE for your battery Th...

Страница 13: ...charging has started by pressing the CHARGE RATE or BATTERY TYPE button the charging process will be restarted The voltage displayed during charging is the charging voltage and usually will be higher...

Страница 14: ...d eventually reduces the charge rate in a controlled manner After the charging process has started the digital display can be used to determine charging progress by selecting the BATTERY mode There ar...

Страница 15: ...k of battery clip Select the batteries requiring more desired charge rate and power than a 30 10 Amp battery type again if charger can deliver within necessary 24 hours The battery may also be faulty...

Страница 16: ...turer or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages...

Отзывы: