background image

4.9 Troubleshooting

 

Version 16.01                                                                          15 /  18

Problem

Cause

Debugging

Main fuse 12 A is defect

Replace main fuse 12 a

The main switchs glows, but

If the main fuse is okey, check if the diode in the power supply

Replace fuse 1,6A in the power supply

the display isn't

is glowing. If not the fuse or the power supply is defect

or replace the power supply

the heating plate isn't heating up

If the diode is glowing

Replace the electronic devices

the electronic devices are defect

The display shows ”Err.5”

Thermal fuse on the heating plate is defect

Replace the thermal fuse

If you use the heating plate 400x500mm replace

both thermal fuses

The display shows ”Err.1”

Thermo couple is defect or the cables to the 

Check the cables to the thermo couple

thermo couple are defect

or exchange the thermo couple

No connection to the heating plate

Put the plug of the heating plat into the socket

The display shows ”Err.2”

The thermo couple is defect

Exchange the thermo couple

The display shows ”Err.3”

Resistance of the thermo couple is too low

Exchange the thermo couple

The display shows ”Err.4”

Resistance of the thermo couple is too high

The display shows ”Err.6”

Power relay CRYDOM is defect

Replace power relay CRYDOM

The display shows ”Err.7”

Adjustment buttons aren't working

Adjustment buttuns are defect

Replace adjusment buttons

No time or temperature adjustments are possible

Temperature of the heating plate doesn't correspond to the 

Malfunction of the electronic devices

Reset the electronic devices, but

Temperature on the display – Temperature too high/low

first contact Walter Schulze GmbH

The press heats up very slowly – over 30 minutes

One of the tow heating elements is defect

Replace the heating plate and/or send it in for repairs

one half of the plate doesn't reach the adjusted temperature

The press will not stay down

Micro switch is defect

Mikroschalter einstellen oder Mikroschalter austauschen

The time is not activated

The Material is to thick and so the micro switch isn't activated

The press will not close

Emergency button is pressed down

Pull the emergency button out

Compressed air is not connected

Connect the compressed air

The press will not open

Pneumatic valve is defect

Replace the pneumatic valve

Содержание Big-O-Lite pneu plus

Страница 1: ...Instruction manual Version 16 01 Heat press Big O Lite pneu plus Version 16 01 1 18...

Страница 2: ...devices 07 3 2 Resetting of the electronic devieces 09 3 3 Error reports 09 3 4 ECO mode 10 3 5 Prepressing 10 3 6 Application range and sample adjustments of the heat press 10 3 7 Pressure settings 1...

Страница 3: ...drawer 14 Handle to pull out the base plate 15 Contact pressure adjustment 16 Compressed air connection 17 Air filter with water separator 18 Extractable handles 19 Main switch 1 3 Technical data Dime...

Страница 4: ...to be replaced The instruction for replacing the main fuse can be found in chapter 4 3 Thermal fuse The thermal fuse is placed directly on the heating plate and it stops the power supply if the temper...

Страница 5: ...press has to be wide enough to let nothing disturb the user at work Using the press with certain materials may create a strong smell That s why the user should evaluate the need for a ventilation sys...

Страница 6: ...o a voltage of 230VAC 50Hz The press is equipped with a plug Make sure that the power outlet is in the right condition and that the grounding is connected to the power outlet Caution please do not con...

Страница 7: ...3 Working with the heat press 3 1 Programming of electronic devices Version 16 01 7 18...

Страница 8: ...er switching on the counter it counts the number of pressing activities a To end the programming of the electronic devices press button 1 b to get to the advanced programming menu press button 1 for 3...

Страница 9: ...press the button YES the Temperature will change to the original setting 3 3 Error reports The electronic devices of the Big O Lite pneu control the main functions of the press Here is a list of poss...

Страница 10: ...All information is supplied without liability please run your own testing before production 3 7 Pressure settings With this press you can change the pressure setting After every change of the pressure...

Страница 11: ...otos 4 6 and the heating plate must be carefully put on soft surface so as not to damage the teflon Then take the new heating plate and tighten it with the wrench Connect the heating plate with the pr...

Страница 12: ...compressor Oil in the system may be damage the press 4 2 Monthly Maintenance Before beginning maintenance work control if the press is turned off and cold Disconnect the press from electricity Some m...

Страница 13: ...e the electronic devices turn off the press and pull the plug Unscrew the cover of the press as in chapter 4 4 Pull out the green plug photo 1 Pull out the electronics keyboard photo 2 Remove the stop...

Страница 14: ...the mat lays exactly over each other 6 Let the glue dry for 24hours 7 Take of the heating plate and cut off the overlaying edge of the silicon mat 4 8 Replacing the thermal fuse The replacing may only...

Страница 15: ...couple is too low Exchange the thermo couple The displayshows Err 4 Resistance of the thermo couple is too high The displayshows Err 6 Power relayCRYDOM is defect Replace power relayCRYDOM The displa...

Страница 16: ...4 10 Connection diagram Version 16 01 16 18...

Страница 17: ...4 11 Controlling of the pneumatics Version 16 01 17 18...

Страница 18: ...K hereby declares that the following machine Heat press serial number is compliant with the specifications of the following EC directives Machinery 2006 42 EC Low Voltage 2014 35 EU EMC 2014 30 EU use...

Отзывы: