7. Measure the distance between points A and B and multiply by 0.7 to give an
approximate depth measurement.
Warnings
Signal Overload
If the Loki receiver is used in areas where very large power signals are present,
the signal bar graph will flash. In this condition the sensitivity control and depth
function will not operate and you are advised to try lifting the Loki receiver to bring
it out of the overloaded condition or use in a different location.
Deactivating
If required the Shallow
Alert™
warnings can be temporarily disabled by pressing
and holding the frequency selection button for the duration of the battery test bleep
at switch on.
Live Plug Connector
Do not use the supplied Direct Connect leads to connect to live cables. Use
the Live Plug Connector or Live Cable Connector. Failure to do so may result in
injury or equipment damage.
Connection to live power cables should only be undertaken by qualified personnel.
The optional Live Plug Connector applies the transmitter signal to a live domestic
power socket and via the domestic wiring system on the service cable and the
supply cable in the street. The signal should be detectable on the supply system to
a few hundred meters each side of the point of application.
Note: Do not connect the Loki transmitter to live cables without using a Live Plug
Connector or Live Cable Connector.