Burner and nozzle specifications
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
(mm)
Thermal power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Thermal
power
kW
(p.c.s.*)
Nozzle
1/100
Flow*
l/h
Nomin.
Ridot.
(mm)
(mm)
***
**
Nomin.
(mm)
Fast (R)
100
3,00
0,70
40
86
218
214
3,00
116
286
Reduced Fast (RR)
100
2,60
0,70
40
80
189
186
2,60
110(Y)
248
Semi Fast (S)
75
1,90
0,40
30
70
138
136
1,90
106
181
Auxiliary (A)
55
1,00
0,40
30
50
73
71
1,00
79
95
Triple Crown (TC)
130
3,30
1,30
57
87
240
236
3,60
131
343
Ultrarapid (UR)
100
3,40
0,70
40
91
240
236
3,40
123
314
Double flame (DCDR
internal)
30
0,90
0,40
30
44
65
64
0,90
70
86
Double flame (DCDR
external) 2 nozzle
130
4,10
1,30
57
70
298
293
4,10
110
390
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
*
At 15°C and 1013 mbar - dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m
3
! The hob can only be installed above built-in ovens with a cooling ventilation system.
DATA PLATE
Electrical
connections
voltage of 220-240V ~ 50/60Hz
(see data plate )
This appliance conforms to the
following European Economic
Community directives:
-73/23/EEC dated 19/02/73 (Low
Voltage) and subsequent
amendments
- 89/336/EEC dated 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 90/336/EEC dated 29/06/90 (Gas)
and subsequent amendments.
- 2002/96/EC
AUX
S R
R
S R
AUX
S R
TC
S R
AUX
S R
RR
S R
UR
TGL 641
TGL 640
TGL 750
TGL 751
AUX
S R
RR
S R
DCDR
Содержание TGL 640