Gas Hob Operating Instructions
Page 6 of 12
Scholtes
Models: PP 30 TC 120 SF
Gas Appr. No: GSCS20141
Natural Gas
1.0kPa
ULPG
2.75kPa
Injector
By-pass*
MJ/h
Injector
By-pass*
MJ/h
Wok
1.65
¾
turn
12.5
0.95
Closed
12
Rapid
1.29
½
turn
8
0.8
Closed
8.5
Semi Rapid
1.1
⅜
turn
6
0.64
Closed
5.3
Aux
0.8
½
turn
3.2
0.5
¼
turn
3.1
Total
29.7
28.9
220-240V AC 50/60Hz 0.6W
Made in EU
* By-pass adjustment is the number of turns anti-clockwise from fully closed position.
~ WARNING 240V. DISCONNECT POWER BEFORE SERVICING THE UNIT.
~ TO BE INSTALLED ONLY BY AN AUTHORISED PERSON