background image

GBA Z 0675 2 E

 

 

BA 

Page 29 of 29 

November 9, 2020 

Last revised 11-2020 

 

Rev. 2 

Scho

ll Ap

parat

eb

au

 G

mb

H & 

C

o

KG

 

 

 

12.3  S

ERVICE ADDRESS

 

 

You can reach us at the following times: 

Monday - Thursday 

from 7:00 a.m. till 4:00 p.m. 

Fridays 

from 7:00 a.m. till 12:15 p.m. 

Outside these office hours please communicate your requests per e-mail or telefax. 

 

Scholl Apparatebau GmbH & Co. KG 

Zinhainer Weg 4  

D-56470 Bad Marienberg / Germany 

Phone 

0049 (0)2661/9868-10 

Telefax 

0049 (0)2661/9868-38 

E-mail 

[email protected] 

Содержание BH/HO/IN 1600 CNS

Страница 1: ...built in Hold Line GN with CNS frame BH HO IN 800 CNS Art No Z 0675 BH HO IN 1600 CNS Art No Z 0676 BH HO IN 2400 CNS Art No Z 0677 BH HO IN 3200 CNS Art No Z 0678 Scholl Apparatebau GmbH Co KG Zinha...

Страница 2: ...echnical specifications 8 3 Installation 9 3 1 Scope of delivery 9 3 2 Requirements of installation 9 3 3 Definition of interfaces 9 3 4 Installation clipping 10 3 4 1 Installation clipping model BH H...

Страница 3: ...struction and use of spare parts 19 6 5 Improper operating methods 19 6 6 Pan detection 19 6 7 Power regulation 19 7 Out of operation 20 8 Fault finding Rectification 21 8 1 Fault finding with error c...

Страница 4: ...fully before starting up this appliance On the following pages you will find important notes regarding its operation care and maintenance so that you will be able to enjoy its use for a long time If a...

Страница 5: ...at the place of operation 1 1 DESCRIPTION OF DANGER SIGNS General hazard symbol Non observance of the safety regulations signifies a hazard injuries Electrical voltage This symbol warns of electric vo...

Страница 6: ...e For holding liquid it is required to use a lid For an amount of more than 4 litres it is recommended to use another high capacity unit 1 2 1 GENERALL INFORMATION ON GN CONTAINER GN Container bottom...

Страница 7: ...to requirements one to four built in heating zones can be connected A temperature range from 50 100 C gives flexibility and allows a perfect food temperature adjustment Simple built in solution thank...

Страница 8: ...588x388x23 mm 557x357 mm Type Voltage Power Heat retention fields temperature operation units BH HO IN 800 230V 0 8kW 1 1 BH HO IN 1600 230V 1 6kW 2 2 BH HO IN 2400 230V 2 4kW 3 2 BH HO IN 3200 230V...

Страница 9: ...pecial attention to the air inlet and air outlet openings there has to be a distance of at least 40mm between obstructions like walls or floors In addition to that pay attention that the exhausted air...

Страница 10: ...0 C The operating staff has to make sure that installation support and inspection is done by qualified personnel 3 4 INSTALLATION CLIPPING 3 4 1 INSTALLATION CLIPPING MODEL BH HO IN 1600 CNS Cut out C...

Страница 11: ...installation heat retention plate As soon as the mounting devices according to the above mentioned steps are finished you may continue with installation Put the heat retention plate with coil and cera...

Страница 12: ...GmbH Co KG 3 5 GENERATOR HO IN 3200 GN Advice for installation generator The rear case of the generator is equipped with two holes for the installation Make sure that the height distance between fan a...

Страница 13: ...GBA Z 0675 2 E BA Page 13 of 29 November 9 2020 Last revised 11 2020 Rev 2 Scholl Apparatebau GmbH Co KG 3 6 MOUNTING VARIATIONS...

Страница 14: ...WITH POTENTIOMETER Advice for installation operation unit This unit is supplied completely with an operation unit In order to fix this on a cover take the clipping for the power switch into account Th...

Страница 15: ...e warning signs and rating plates on the units must strictly be followed Check and ensure that the supply voltage and the line current match the specifications given on the rating plate Max tolerance...

Страница 16: ...be heated Take the serving pan away from the heat retention area power transmition stops Place the serving pan back on the heat retention area the heating retention process will continue Turn the con...

Страница 17: ...pots or pans with a lid if fluids are kept warm Pots and pans must not be over 100 C when placed on the heat retention plate this may lead to damages of the glass or to a safety cutoff 5 1 COMFORT The...

Страница 18: ...ss to continue automatically when a serving pan is placed back on the heat ing area So if a person starts to use the induction unit he she will have to start the heating process by turning the control...

Страница 19: ...he manufac turer if you intend to make any changes To guarantee safety just use genuine spare parts and accessories authorized by the manufacturer The use of other components will void all warranty 6...

Страница 20: ...Co KG 7 OUT OF OPERATION If the induction unit is out of operation make sure that the control knob is in the OFF position If you do not use the unit for a long period several days unplug the unit Mak...

Страница 21: ...induction appliance must only be opened by authorized and trained service personnel CAUTION Do not open the unit dangerous electric voltage inside Stop any actions if the heating area ceran plate is...

Страница 22: ...tral unit power unit not connected 1 Check wiring Connect coil and BUS port E12 Reduction heat sink temperature T 75 C 2 Check installation Airflow E20 Reduction internal temperature T 70 C 2 Check in...

Страница 23: ...unit from the electrical supply and contact your service partner Poor heating 7 segment display is ON shining Used pan is not appropriate Use a SCHOLL GN equipment recommended for induction heat rete...

Страница 24: ...nit off remove Chafing Dish or cast iron pan and fill water into the pan let unit cool down Empty cooking no water in the pan The cooling system fan starts to operate when the ambient temperature in t...

Страница 25: ...Sugar sugar containing food plastic aluminum foil Immediately scrape off the sugar plastic or aluminum foil residues thoroughly from the hot cooking area e g with a razor blade After removal of the re...

Страница 26: ...regular cleaning care and servicing The operator has to ensure that all components relevant for safety are in perfect working order at all times The induction unit should be examined at least once a...

Страница 27: ...therwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal ser...

Страница 28: ...nce will be accepted Further warranty information is contained in our General Terms and Conditions of Sale or can be made available upon request Appliances not produced by ourselves are subject to the...

Страница 29: ...the following times Monday Thursday from 7 00 a m till 4 00 p m Fridays from 7 00 a m till 12 15 p m Outside these office hours please communicate your requests per e mail or telefax Scholl Apparateba...

Отзывы: