8. To increase the contact pressure, you must reduce the distance between the
metering brush and the sieve insert. To do this, turn the eccentric axles (41) so that
the distance of the flock funnel (34) is reduced.
9. To reduce the contact pressure, you must increase the distance between the
metering brush and the sieve insert. To do this, turn the eccentric axes (41) so that
the distance between the eccentric axes and the upper edge of the flock funnel
increases.
10. Tighten the screws (35) of the eccentric axes (41).
11. Place the sieve (39) in the funnel (34) with the bulge facing downwards.
12. Press the sieve firmly until it rests on the eccentric axles (41) located in the flock
funnel.
13. Place the flock hopper (34) with the sieve (39) facing upwards under the flock supply
container (14).
14. Lock the flock funnel (34) by first pushing the lever of the quick release on the left
(32) and then on the right (33) upwards.
15. Close the service flap (12) with the supplied triangular key.
16. Restore the power supply.
12.3. Changing the dosing brush
Replacement of the dosing brush (38) can be considered if the spiral brush coating is worn or
if the flock funnel or the dosing brush are to be cleaned. Cleaning is recommended whenever
a flock change is performed.
The procedure for changing the dosing brush includes the work sequences for removing the
dosing brush and installing the dosing brush. These work sequences are described below.