7.3. Flocking
Flocking processes can be performed or terminated by pressing or releasing the button (13)
of the flocking gun.
When the switch is pressed, the Operation LED (22) starts to light up in green. This lights up
as long as the button remains pressed. The blower is then briefly ramped up to maximum
speed. Afterwards, the speed is reduced to the value set with the Blower Up/Down keys (17).
Due to the ramp-up to the maximum speed, a stronger sound emission is generated for a short
time than is the case in continuous operation of the AFP. Any flock in the air hose (36) is blown
out when the blower is ramped up. The metering brush (38) is then rotated and flock is metered
out. The high voltage set with the HS Up/Down keys (16) is then generated.
When the button is released, the blower is shut down, the dosing brush is stopped and the
high voltage is discharged. The LED flashes until the voltage is completely discharged. The
LED then goes out.
8. Site of installation
This chapter describes the conditions that must be met by a suitable installation site so that
the AFP can be operated properly and professionally. The overall view of the AFP with the
part markings can be found on the last page of these operating instructions.
8.1. Conditions for a suitable installation site
A suitable installation site for the AIR Flocker PRO must meet the following conditions:
- The installation site must be covered and dry. This prevents damage to the AFP due
to humidity and moisture.
- The base must be firm and level. This ensures that the AFP stands firmly and
securely and cannot be displaced by vibrations.
- The base must be free of impurities such as dust, etc., so that these cannot be
sucked in by the blower via the suction port and block the air hose if necessary.
- An unobstructed air supply must be ensured so that the blower does not overheat.
To this end, a minimum distance of 10 cm must be maintained from boundary
surfaces.
- The unimpeded opening of the lid of the flock reservoir container (14) must be
ensured.
- The unimpeded opening of the service flap (12) must be ensured.