9.6.
Description of the status bits
Byte Bit
Status bit
Explanations
0
0
High voltage is ON
1: Output voltage larger than 90% of
voltage target value and the power
module working.
0: no high voltage
1
Collective malfunction
1: If any individual malfunction oc-
curs.
0: no malfunction
2
Collective warning
1: If any individual warning occurs.
0: no warning
3
Device is safely off
1: Output voltage is smaller as safety
voltage.
No error is present.
The safety relay is energized.
0: The device is in error state and/or
unsafe.
4
OPENED safety contact
1: Safety relay failed.
0: Safety relay energized.
5
Left button
1: Left button pressed.
0: Automatically reset if the status
word is queried via SYN object.
6
Right button
1: Right button pressed.
0: Automatically reset if the status
word is queried via SYN object.
7
Reserve
1
0
Operating mode
1: U-mode
0: I-mode
No effect.
If the current target value is reached
before the voltage target value, the
current is restricted, i.e. I-mode. U-
mode is the opposite.
1
Fan speed (internal fan)
1: Fan speed is less than 80% of the
specified value.
0: Fan speed OK
Содержание 810353
Страница 1: ...1 Item no 810353 120 kV 2 mA Operating manual HV supply HER02 02...
Страница 9: ...Operating manual 810353 BALDE 150220 Version 20 02 2015 Page 9 of 36 4 3 Fastening dimension sheet 6 4...
Страница 34: ...Operating manual 810353 BALDE 150220 Version 20 02 2015 Page 34 of 36 9 9 Overview of control and status word...
Страница 35: ...Operating manual 810353 BALDE 150220 Version 20 02 2015 Page 35 of 36 9 10 Object directory...