UNM
II/5
GB
2.6.11 Cleaning/replacing the check
valve
1. Unscrew the locking screw (Figure 6a).
2. Clean insert, replace in case of damage,
squeezing or hardening.
3. Clean seat, replace complete check valve
if damaged.
2.6.12 Replacing the safety valve
1. Detach the safety valve (item 11) by un-
screwing it anticlockwise.
2. Apply Loctite® 243 to the thread of the
new safety valve or wind Teflon tape
around the valve.
3. Screw the new safety valve into place by
screwing it clockwise.
2.7 Decommissioning
2.7.1 Preservation
Oil-lubricated compressors: compressor is
taken out of service for a long period (over 6
months) or is new from the factory and will
not be operated until much later.
1. Replace oil with corrosion inhibitor oil
(viscosity SAE 30). See Chap. 2.6.7.
2. Allow the compressor to warm up, switch
it off, disconnect the power supply.
3. Drain the condensate, depressurise the
compressor.
4. Prior to returning to operation, replace
corrosion inhibiting oil with compressor
oil.
Store the compressor in a dust-free and dry
area where it is not exposed to high temper-
ature fluctuations.
2.7.2 Disposal
Dispose of the unit and packaging materials
according to applicable regulations.
2.8 Troubleshooting
Problem
Cause
Remedy
A Protective motor
switch interrupts
power supply
In case of malfunctions (e.g.
overheating; low voltage;
extension cable too long or
with incorrect cross-section),
the protective motor switch is
tripped.
X
Switch off the compressor. Wait
a short while. Actuate the protec-
tive motor switch is available.
Switch on the compressor.
Protective motor switch trips
again: switch off compressor.
Disconnect the power supply.
Contact the service partner
B Pressure relief does
not function
Power failure / undervoltage in
mains with compressor
switched on
X
Switch off the compressor. It de-
pressurises. Switch on the com-
pressor
C Compressor does
not start when
switched on.
Vessel pressure is higher than
switch-on pressure.
X
Relieve pressure in the vessel
until the pressure switch is acti-
vated automatically.
Power supply faulty.
X
Have the power supply checked
by a qualified person (service
partner).
Protective motor switch inter-
rupts power supply.
X
See item A.
Pressure switch defective
X
Have the pressure switch
changed by a qualified person.
D Compressor starts
up briefly / buzzes
and then switches
off automatically
Mains connection cable longer
than permitted or the cross
section is too small
X
Check connection cable length
and cable cross-section (see
Chap. 2.4.4)
Содержание UNM 580-15-90 DX
Страница 3: ...2a 4a 3a 5a 8a 6a 7a 8b...
Страница 79: ...UNM II 63 RUS 2 3 Schneider Druckluft GmbH 38 2 4 2 4 1 2 4 2 2 4 3 1 2 3 2 6 6 L X X X X X X...
Страница 84: ...II 68 UNM RUS C X X A X D X 2 4 4 E X X X X 2 6 5 X X F X G X 2 6 11 X H X 2 6 5 X E...
Страница 85: ...UNM II 69 RUS 2 9 I X X J X X X K X X L X X 2 6 10...