II/ 10
SLM
GB
2.9 Troubleshooting
Observe the safety instructions and maintenance instructions!
*For troubleshooting: refer to the information in the "Technical data" chapter in part 1 of the instruction manual!
**See Chapter: "Intended use" in Instruction manual part 1!
***For troubleshooting: read chapter: "Commissioning"!
****For troubleshooting: read chapter: "Maintenance"!
If necessary, contact our service staff, see last page.
Problem
Cause
Remedy
A Minimum or no
operating capacity
Air regulation (item 03) set-
ting incorrect
X
Adjust the air regulation setting
correctly
***
Abrasive / Tool worn
X
Replace abrasive / tool
*
Working pressure (flow pres-
sure) too low
X
Increase working pressure (flow
pressure) Observe maximum
working pressure
*
Compressor output too small
X
Use different output
rating
*
Hose diameter too small
X
Use correct hose diameter
*