AR100 Operation Manual
© 2018 Schmitt Industries
Revision 1.1
18
07h
Reserved
08h
Lower byte of the sampling
period
1) 10…65535 (default — 5000)
The time interval in increments of 1 μs with
which sensor automatically communicates
the results on streaming request (priority of
sampling = 0).
2) 1…65535 (default — 5000)
Divider ratio of trigger input (priority of
sampling = 1).
09h
Higher byte of the sampling
period
0Ah
Lower byte of maximum
integration time
2…3200 (default – 3200)
The limiting time of integration by CMOS-
array in increments of 1 μs.
0Bh
Higher byte of maximum
integration time
0Ch
Lower byte for the
beginning of analog output
range
0…16383 (default – 0)
0Dh
Higher byte for the
beginning of analog output
range
0Eh
Lower byte for the end of
analog output range
0…16383 (default – 16383)
0Fh
Higher byte for the end of
analog output range
10h
Time lock of result
0…255, specifies the time interval in
increments of 5 milliseconds.
11…16h
Reserved
17h
Lower byte of a zero point 0…16383 (default — 0), specifies the
beginning of absolute coordinate system.
18h
Higher byte of a zero point
19…88h
Reserved
89h
Autostart of the stream
when the sensor is turned
on (after 20 seconds)
1 — Autostart is ON;
0 — Autostart is OFF (default).
8Ah
Protocols for RS232/RS485
interfaces
0 — ACUITY protocol (default);
1 — ASCII protocol;
2 — MODBUS RTU protocol.
Notes
•
All values are given in binary form.
•
Base distance and range are given in millimeters.
•
The value of the result transmitted by a sensor (D) is so normalized that
4000h (16384) corresponds to a full range of the sensor (S in mm),
therefore, the result in millimeters is obtained by the following formula: