![Schmidt MV3 Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/schmidt/mv3/mv3_operation-and-maintenance-manual_1213591043.webp)
43
Copyright © 2021 Axxiom Manufacturing, Inc.
7.2 Beginning the Blasting Operation (See Figure 7.1 or 7.2)
7.2.1. The abrasive blaster must be properly setup and all operating personnel must be
thoroughly trained before beginning the blast operation. All operators must completely
read and understand all sections of this manual before beginning the blast operation. See
the pre-operation setup procedures given in Section 6.0.
7.2.2. Perform the required inspections and maintenance before beginning the blast operation.
See the instructions given in Section 8.0.
The abrasive blaster is a Pressurized Vessel. Propelled objects will cause serious injury
or death. Depressurize vessel before performing any maintenance. See Section 6.2.
7.2.3. Open the abrasive shutoff valve (optional, see Section 5.13).
7.2.4.
Open the choke valve (#13). Always leave the choke valve completely open while
blasting. Close the choke valve only for the “choke” procedure (see Section 11.3.2.). Do
Not blast for long periods with the choke valve partially closed since this will cause
excessive wear in the MV3 Valve (#14).
7.2.5.
For initial startup, the MV3 Valve (#14) should only be partially open. Turn the valve
knob clockwise to completely close, then turn counterclockwise about four turns to
partially open. The best setting for the valve varies depending on abrasive type, blast
pressure, and nozzle size; therefore, it may take more than one adjustment to achieve the
desired air/abrasive mixture. Further adjustment can be made later as needed.
7.2.6. Slowly open the inlet ball valve (#3). This will supply air to the ComboValve® (#4) and
the deadman controls (#12 & #15). The blast vessel will not pressurize.
7.2.7. Slightly open the ball valve (#8) on bottom of the moisture trap (#7) to permit moisture
to continually drain during the blast operation (optional, see Section 5.4). Once each day
completely open the drain ball valve to blow out all moisture and dirt particles.
7.2.8. The following steps are for abrasive flow setting which may require several adjustments
and testing of the blast flow. It is recommended that testing of the blast be made on a
test piece so not to damage anything of value.
7.2.9.
With one hand grip the blast hose assembly (#10) and with the other hand press in the
deadman safety button.
To begin blasting, aim the blast nozzle at the object to be
blasted, then firmly press down the deadman lever (#12). The ComboValve® will open
and pressurize the abrasive blaster. Air and blast abrasive will flow into the blast hose
and out through the blast nozzle (#11).
Do Not aim the blast nozzle towards yourself or any person. A system malfunction or a
blocked blast nozzle that clears can trigger accidental start up resulting in injury to
personnel.
7.2.10. Observe the blast stream and the coating removal rate. A bluish color in the blast stream
indicates a good abrasive to air mixture. Release the deadman lever to stop blasting
.
Содержание MV3
Страница 18: ...18 Copyright 2021 Axxiom Manufacturing Inc 2 7 Abrasive Blaster Strapping Packing Detail ...
Страница 36: ...36 Copyright 2021 Axxiom Manufacturing Inc THIS PAGE IS INTENTIONALLY BLANK ...
Страница 53: ...53 Copyright 2021 Axxiom Manufacturing Inc 9 1 MV3 Valve Abrasive Blaster Pneumatic Control 1 5 cu ft ...
Страница 54: ...54 Copyright 2021 Axxiom Manufacturing Inc 9 2 a MV3 Valve Abrasive Blaster Pneumatic Control 3 5 20 cu ft ...
Страница 56: ...56 Copyright 2021 Axxiom Manufacturing Inc 9 3 a MV3 Valve Abrasive Blaster Electric Control 3 5 20 cu ft ...
Страница 58: ...58 Copyright 2021 Axxiom Manufacturing Inc 9 4 MICROVALVE ...
Страница 59: ...59 Copyright 2021 Axxiom Manufacturing Inc 9 5 a MV2 Valve ...
Страница 60: ...60 Copyright 2021 Axxiom Manufacturing Inc 9 5 b MV3 Valve ...
Страница 61: ...61 Copyright 2021 Axxiom Manufacturing Inc 9 6 COMBOVALVE ...
Страница 62: ...62 Copyright 2021 Axxiom Manufacturing Inc 9 7 Control Valves pneumatic and electric ...
Страница 63: ...63 Copyright 2021 Axxiom Manufacturing Inc 9 8 a G2 Pneumatic Deadman ...
Страница 64: ...64 Copyright 2021 Axxiom Manufacturing Inc 9 8 b Deadman Valves Pneumatic ...
Страница 66: ...66 Copyright 2021 Axxiom Manufacturing Inc 9 10 Volumetric Blowdown Suppression System VBS II ...
Страница 77: ...77 Copyright 2021 Axxiom Manufacturing Inc NOTES ...
Страница 78: ...78 Copyright 2021 Axxiom Manufacturing Inc NOTES ...