background image

Schmidt 

Mess- und Regeltechnik

 

©2013 Schmidt 

Mess- und Regeltechnik

  

Fon 0 67 32 - 91 91 20        Fax 0 67 32 - 96 24 42        [email protected] 

Operation Manual Flow Transmitter DW-D 

2.3

    

Items with WELDED SOCKET

 

 

 

 

The welding socket is included in the delivery. Remove by loosening union nut (A). The 
dimensions shown in the drawing (right) must be adhered to strictly to. Drill a ridge less hole in 
the pipe. Weld the socket to the pipe. Mount the flow transmitter to the socket ensuring that 
the pendulum is not damaged during this procedure. Align the transmitter into the final desired 
position before tightening the union nut (A). Please do not forget to keep the flow direction in 
consideration before weld on the socket. (groove) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2.4 

Torsional moment of the union nut

  

 

If the device shall be divided from the t-piece or the welding socket, the union nut has to be 
disconnected and the device carefully taken out of the housing. 

 

If both pieces are assembled, please take care that the nut is tightened with a torsional 
moment of 40Nm. 

 

 

Содержание DW-D

Страница 1: ...the DW D may not directly taken close to 230V or 380V wirings The device should not be installed close to inductance switching loads engines or similar sources of inductive fields 1 3 Direction of Flow It is essential that the unit is mounted so that flow is as indicated by the arrow on the body The unit will not operate unless installed correctly in this way and the possibility of damage to the u...

Страница 2: ...cket to the pipe Mount the flow transmitter to the socket ensuring that the pendulum is not damaged during this procedure Align the transmitter into the final desired position before tightening the union nut A Please do not forget to keep the flow direction in consideration before weld on the socket groove 2 4 Torsional moment of the union nut If the device shall be divided from the t piece or the...

Страница 3: ...de of the enclosure The button P has the function to choose a point of the menu and to take over the wished values With the buttons and you can set a value Button increases value Button decreases the value Pressing this button one time the value changes for one digit If you keep the buttons on hold the value is changing continuously After some time velocity is increasing At some points of the menu...

Страница 4: ...ting the switch point of RELAIS 1 is now completed Actuate P button once more causes changing to RELAIS 2 Adjustment is like described under RELAIS 1 When the adjusted value is reached a lamp glows for control The green one A is assigned to RELAIS 1 the red one to RELAIS 2 B 4 3 Adjusting of output occupancy DW D comes with current voltage and frequency output The different output types only can b...

Страница 5: ...present at the time of power failure This guarantees that the operator is aware of that power supply was interrupted and so the amount indicated perhaps not corresponds to the real quantity Attention The power failure supervising function only works if at menu point BATT CHECK see 4 1 the function is activated ON The device has a 8 digit display so a big capacity is available Nevertheless dependin...

Страница 6: ...put impermissible values will normally be transferred These are 1mA 20V respectively 0 Hz In order to re establish the function of the item in such a case the necessary software is saved additionally for safety reasons The software can be load again with the menu item FACTORY RESET Therefore push the button or in the menu FACTORY RESET You will be asked to start the action Y button or to break up ...

Страница 7: ...oy the calibration Clean the pendulum system before re installing into the pipe IMPORTANT If the DW D must be separated from the tee loosen nut A and cant the unit a little opposed to direction of flow Then lift the DW D with pendulum rectangular out of the tee Please perform all disassembly reassembly operations with great care Avoid damage Especially to the pendulum system 6 TECHNICAL DATA Power...