EFA stunning device Original operating instructions
EN
Rev.01
– 01.2021
17 of 28
Fig. 6.7
– MEVB 100 (VB 215, VB 225)
2
Not completely inserted bolt
An unfavourable positioning or movement of the animal's head in relation to the stunner can jam the bolt while
withdrawing. Therefor the bolt does not automatically return to the initial position. In order to get the bolt back
into the initial position, a blank shot must be fired without the use of an animal. The
"MEVB 100"
is
recommended for this.
6.2.3
Blank shot with MEVB 100
Danger!
Perform blank
shots only with
MEVB 100. Danger
through shooting
bolt.
Danger!
In the event of incorrect
usage, there is a direct risk
of injury from kickback and
damage from the stunning
device.
Without operating the release lever (1),
insert the
stunner perpendicular into the guid tube of the
attachment until it reaches the end.
Press the release lever (1). Shot fired.
Release the release lever.
Take the stunner out of the mount.
If the bolt is in the initial position the stunner is ready
for usage again.
Caution!
If the bolt is not fully retracted prior to
the stunning, the stunning device will
kick back when firing.
Fig. 6.8
– MEVB 100 (VB 316)
2
Attachment
Bracket
No
Fig. 6.5
– MEVB 100
Fig. 6.6
– MEVB 100
Safety
button
Attachment
Guide
1
1
1
Yes