1 Important notes
Definition of individual target groups
Project engineers for safe drive systems:
Engineers and technicians
Assembly, electric installation, maintenance and replacement of devices:
Maintenance electricians and service technicians
Commissioning, operation and configuration:
Technicians and engineers
1.1 Definitions
The designation PSCBR is used as generic term for all derivatives from the PSCBR product
range. Wherever this description refers to a certain derivative, the complete designation is
used.
The term "safe" used in the following text in any case refers to the classification as a safe
function for application up to Pl e acc. to EN ISO 13849-1 or SIL3 acc. to EN 61508.
The system software "SafePLC" serves the purpose of configuring and programming PSCBR
modules.
The modules of the PSCBR series are internally built up of two independent processing units.
In the following these are referred to as system A and system B.