Operating instructions

Safety-monitoring module

PROTECT SRB 101EXi-1A

EN

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of  

the safety-monitoring module, personal hazards or damage 

to machinery or plant components cannot be excluded. 

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages resulting 

from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary repairs, 

conversions and modifications to the device are strictly forbidden; the 

manufacturer shall accept no liability for damages resulting from such 

invasive work, arbitrary repairs, conversions and/or modifications to  

the device.

2  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

PROTECT SRB 101Exi-1A

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and there-

fore the compliance with the Machinery Directive and the 

Explosion Protection Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond  

to the standard version.

2.3  Destination and use

The safety inputs of the SRB 101EXi-1 safety-monitoring module have 

an intrinsically safe design according to EN 60079-11. As appropriate 

intrinsically safe apparatus, the SRB can evaluate sensors located in 

the Zone 2 / 22, 1/21 and must be installed outside of the Ex-area in  

a suitable control box or control cabinet.

The SRB 101EXi-1A safety-monitoring module can also be used in 

Zone 2 areas, when mounted in a suitable enclosure with at least IP 54  

protection class to EN 60079-15. The relay contacts for the safety 

 enabling signal are designed with protection class nC, the terminals  

for the supply with nA and those for the signal inputs with ib.

The safety function is defined as the opening of release 13-14 when 

the inputs S11-S12 or S21-S22 are opened. The safety-relevant current 

path with output contact 13-14 meets the following requirements under 

observation of a B

10d

 value assessment (also refer to “Requirements of 

DIN EN ISO 13849-1“):

– Control category 4 - PL e to DIN EN ISO 13849-1 

– SIL 3 to DIN EN 61508-2 

–  SILCL 3 to DIN EN 62061  

(meets the requirements of control category 4 to DIN EN 954-1)

To determine the Performance Level (PL) of the entire safety function 

(e.g. sensor, logic, actuator) to DIN EN ISO 13849-1, an analysis of all 

relevant components is required.

2.4  Technical data

General data

Standards:

IEC/EN 60204-1, EN 60947-5-1;  

EN ISO 13849-1, IEC/EN 61508

Climate resistance:

EN 60068-2-78

Fixing:

Snaps onto standard DIN  

rails to DIN EN 60715

Terminal designations:

EN 60947-1

Material of the enclosure:

glass-fibre reinforced 

thermoplastic, ventilated

Material of the contacts:

AgSnO, self-cleaning, positive drive

Weight:

aprox.230 g

Start conditions:

Automatic or start button 

Feedback circuit (Y/N):

Yes

Pull-in delay with automatic start: typ. 300 ms

Drop-out delay in case  

of emergency stop:

typ. 20 ms

Drop-out delay  

on "supply failure":

typ. 20 ms

Bridging in case 

of voltage drops:

typ. 15 ms

Mechanical data

Connection type:

Screw terminals

Cable section:

min. 0.25 mm

2

 / max. 2.5 mm

2

Connecting cable:

rigid or flexible

Tightening torque  

for the terminals:

0.6 Nm

With removable  

terminals (Y/N):

No

Mechanical life:

10 million operations

Electrical life:

Derating curve available on request

Resistance to shock:

10 g / 11 ms

Resistance to vibrations  

to EN 60068-2-6:

10 ... 55 Hz, amplitude 0.35 mm

Ambient conditions

Ambient temperature:

–25°C … +60°C

Storage and transport  

temperature:

–40°C … +85°C

Protection class:

Enclosure: IP 40

Terminals: IP 20

Wiring compartment: IP 54

Air clearances and  

creepage distances

IEC 60664-1: 4 kV/2  

(basic insulation), EN 60079-11

EMC rating:

to EMC Directive

Electrical data

Contact resistance  

in new state:

max. 100 mΩ

Power consumption:

max. 3.0 W

Rated operating voltage U

e

:

24 VDC –15% / +20%,  

residual ripple max. 10%

Frequency range:

50 Hz / 60 Hz

Max. fuse rating of  

the operating voltage:

internal fuse: 

– F1: T 50 mA / 250 V

– F2: T 100 mA / 250 V

Monitored inputs

Cross-wire detection (Y/N):

Yes

Wire breakage detection (Y/N): Yes

Earth leakage detection (Y/N): Yes

Number of NO contacts:

0

Number of NC contacts:

2

Cable lengths:

see EX-relevant Data:

Conduction resistance:

see EX-relevant Data:

Outputs

Number of safety contacts:

1

Number of auxiliary contacts:

1

Number of signalling outputs:

0

Switching capacity of  

the safety contacts:

13-14:

max. 230 V, 3 A ohmic  

(inductive in case of appropriate  

protective wiring) min. 10 V / 10 mA

Switching capacity of  

the auxiliary contacts:

24 VDC / 2 A

Содержание PROTECT SRB 101EXi-1A

Страница 1: ...to execute safety related functions as part of an entire plant or machine It is the responsibility of the manufacturer of a machine or plant to ensure the proper functionality of the entire machinery or plant The safety monitoring module must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the ra...

Страница 2: ...vation of a B10d value assessment also refer to Requirements of DIN EN ISO 13849 1 Control category 4 PL e to DIN EN ISO 13849 1 SIL 3 to DIN EN 61508 2 SILCL 3 to DIN EN 62061 meets the requirements of control category 4 to DIN EN 954 1 To determine the Performance Level PL of the entire safety function e g sensor logic actuator to DIN EN ISO 13849 1 an analysis of all relevant components is requ...

Страница 3: ...aps onto standard DIN rails to EN 60715 Snap the bottom of the enclosure slightly tilted forwards in the DIN rail and push up until it latches in position 3 2 Mounting of the sensors The installation of the intrinsically safe current circuits must be executed in accordance with the applicable standards EN 60079 14 or EN 61241 14 According to EN 60079 11 the following must be observed for the insta...

Страница 4: ... enabled 5 4 Adjustment Opening the front cover see Fig 3 To open the front cover insert a slotted screwdriver in the top and bottom cover notch and gently lift it When the front cover is open the electrostatic discharge requirements must be respected and observed After setting the front cover must be fitted back in position Setting the switch see Fig 4 The cross wire short monitoring function fac...

Страница 5: ...ccordance with the national prescriptions and legislations 8 Appendix 8 1 Wiring examples Dual channel control shown for a guard door monitor with two position switches where one has a positive break contact with external reset button J Fig 6 Relay outputs Suitable for 2 channel control for increase in capacity or number of contacts by means of contactors or relays with positive guided contacts Th...

Страница 6: ...o DIN EN ISO 13849 1 possible Dual channel guard door monitoring circuit with interlocking device to EN 1088 Fig 13 At least one contact with positive break required Wire breakage and earth leakage in the control circuits are detected Cross wire shorts between the control circuits are not detected For the safety circuits monitoring the interlocking devices may be designed as simple electrical appa...

Страница 7: ...B 101EXi 1A must be wired to the simple electrical apparatus Requirements for the intrinsically safe current circuit The enclosures have at least protection class IP 54 EN 60529 for gas IP6X for dust IP5X in case of non conductive dusts in Zone 22 9 1 Devices that can be used as simple electrical apparatus On the basis of a valid declaration of the manufacturer with an assess ment as simple electr...

Страница 8: ...4 9 EC EC Explosion Protection Directive ATEX 2004 108 EC EMC Directive Affixing of the CE conformity mark 1 for safety components whose type plate is labelled safety component Used harmonized standards EN 60079 15 EN 61241 0 EN 61241 11 EN 60079 0 EN 60079 11 Person authorized for the compilation of the technical documentation Ulrich Loss Möddinghofe 30 42279 Wuppertal Notified body TÜV Rheinland...

Отзывы: