S
CHMALZ
SCP
I
/
SMP
I
3-8
Setting the blow-off volume flow
The valve screw for setting the blow-off volume flow is located underneath the vacuum con-
nection. The volume flow is reduced by turning the valve screw clockwise and increased by
turning it anti-clockwise. The valve screw is equipped with a stop on both sides.
Do not overwind the stop on the valve screw. A minimum volume flow of approx.
20% is always necessary for technical reasons.
The blow-off volume flow can be set between 20% and 100%.
3 D
ESCRIPTION
Version overview
Product name
Art.-Nr.
SMPi 20 IMP RD M12-8-PT SO (cpl. with connection distributor)
10.02.02.04441
SMPi 20 IMP RD M12-8-PT SO (without connection distributor)
10.02.02.04442
SMPi 25 IMP RD M12-8-PT SO (cpl. with connection distributor)
10.02.02.03480
SMPi 25 IMP RD M12-8-PT SO (without connection distributor)
10.02.02.03334
SMPi 25 IMP ISO_01 RD M12-8-PT SO(without connection distributor)
10.02.02.03649
SMPi 25 IMP ISO_01 RD M12-8-PT SO(cpl. with connection distributor)
10.02.02.03650
SMPi 25 IMP ISO_02 RD M12-8-PT SO(without connection distributor)
10.02.02.03646
SMPi 25 IMP ISO_02 RD M12-8-PT SO(cpl. with connection distributor)
10.02.02.03648
Connection distributor ASV SMPI/SCPI 2xM12-4
10.02.02.03335
Содержание SMPi 20
Страница 13: ...SCH MAL Z SCPI SMPI 3 13 Operating modes ...
Страница 41: ...SCH MAL Z SCPI SMPI 7 41 Electric Connection Internal wiring of electrical isolation ...
Страница 45: ...SCH MAL Z SCPI SMPI 7 45 Pneumatic circuit plans SMPi IMP SMPi IMP ...
Страница 48: ...SCH MAL Z SCPI SMPI 8 48 8 DECLARATION OF CONFORMITY ...