S
CHMALZ
SCP
I
/
SMP
I
7-47
Symbol Function
Comment
“External” blow-off
Selection of externally controlled blow-off
“Internal” blow-off
Selection of internally controlled blow-off (triggered internally;
time can be set)
Display
Selection of the display menu for rotating the display screen
Display top
Display screen not rotated (standard)
Display bottom
Display screen rotated by 180°
PIN code
Entry of the PIN code for unlocking the menu
“Clear all” (reset)
All values are reset to the factory settings.
Menu locked
The keypad and menus remain locked after an incorrect PIN
code is entered.
Menu unlocked
The buttons and menus are unlocked.
F
ACTORY SETTINGS
Symbol Function
Factory setting
H1 switching point
750 mbar
h1 hysteresis
150 mbar
H2 switching point
550 mbar
h2 hysteresis
10 mbar / 100 mbar
*
Vacuum unit
Vacuum unit (in mbar)
Signal type
PNP switch
Configuration of
output
Normally open contact
Air-saving function
Ejector with air-saving function:
Blow-off function
Externally controlled blow-off
Display
Display screen not rotated
PIN code
*
The hysteresis 100mbar applies to the ejectors 10.02.02.04441and 10.02.02.04442,
SMPi 20 IMP RD M12-8-PT SO (with and without connection distributor)