IO Link Data Dictionary
SCPMi
21.10.01.00125
14.06.2019
J. Schmalz GmbH
Johannes Schmalz Str. 1, D 72293 Glatten
Tel.: +49(0)7443/2403 0
Fax: +49(0)7443/2403 259
[email protected]
69
0x0045
0
bLo
1 byte
0 2
rw
0
0 = Externally controlled blow off ( E )
1 = Internally controlled blow off – time dependent (I t)
2 = Externally controlled blow off – time dependent (E t)
71
0x0047
0
Ou2
1 byte
0 1
rw
0
0 = NO
1 = NC
73
0x0049
0
P n
1 byte
0 1
rw
0
0 = PNP
1 = NPN
74
0x004A
0
uni
1 byte
0 3
rw
0
0 = mbar
1 = kPa
2 = inHg
3 = psi
75
0x004B
0
dLY
2 byte
0 999
rw
10
Unit: 1 ms
76
0x004C
0
Eco
1 byte
0 2
rw
0
0 = off
1 = on (full eco mode with display switching off completely)
2 = Lo (medium eco mode with display dimmed to 50%)
79
0x004F
0
dIS
1 byte
0 1
rw
0
0 = Standard
1 = Rotated
275
0x0113
P n
1 byte
ro
Number of the active profile: 0 3
68
0x0044
0
Ctr
1 byte
0 2
rw
1
0 = not active (off)
1 = active (on)
2 = active with supervision (onS)
78
0x004E
0
dCS
1 byte
0 1
rw
0
0 = off
1 = on
100
0x0064
0
SP1
2 bytes
999 > SP1 > rP1
rw
750
Unit: 1 mbar
101
0x0065
0
rP1
2 bytes
SP1 > rP1 > SP2 rw
600
Unit: 1 mbar
102
0x0066
0
SP2
2 bytes
rP1 > SP2 > rP2
rw
550
Unit: 1 mbar
103
0x0067
0
rP2
2 bytes
SP2 > rP2 >= 10
rw
540
Unit: 1 mbar
106
0x006A
0
tbl
2 bytes
10 9999
rw
200
Unit: 1 ms
107
0x006B
0
t 1
2 bytes
0 9999
rw
2000
Unit: 1 ms. No t 1 Warning if set to 0
108
0x006C
0
L
2 bytes
0 999
rw
250
Unit: 1 mbar/sec. No L Warning if set to 0
119
0x0077
0
1...32 bytes
rw
***
180
0x00B4
0
1 byte
0 2
rw
1
181
0x00B5
0
1 byte
0 1
rw
0
182
0x00B6
0
2 bytes
999 > SP1 > rP1
rw
750
183
0x00B7
0
2 bytes
SP1 > rP1 > SP2 rw
600
184
0x00B8
0
2 bytes
rP1 > SP2 > rP2
rw
550
185
0x00B9
0
2 bytes
SP2 > rP2 >= 10
rw
540
186
0x00BA
0
2 bytes
10 9999
rw
200
187
0x00BB
0
2 bytes
0 9999
rw
2000
188
0x00BC
0
2 bytes
0 999
rw
250
199
0x00C7
0
1...32 bytes
rw
***
200
0x00C8
0
1 byte
0 2
rw
1
201
0x00C9
0
1 byte
0 1
rw
0
202
0x00CA
0
2 bytes
999 > SP1 > rP1
rw
750
203
0x00CB
0
2 bytes
SP1 > rP1 > SP2 rw
600
204
0x00CC
0
2 bytes
rP1 > SP2 > rP2
rw
550
205
0x00CD
0
2 bytes
SP2 > rP2 >= 10
rw
540
206
0x00CE
0
2 bytes
10 9999
rw
200
207
0x00CF
0
2 bytes
0 9999
rw
2000
208
0x00D0
0
2 bytes
0 999
rw
250
219
0x00DB
0
1...32 bytes
rw
***
220
0x00DC
0
1 byte
0 2
rw
1
221
0x00DD
0
1 byte
0 1
rw
0
222
0x00DE
0
2 bytes
999 > SP1 > rP1
rw
750
223
0x00DF
0
2 bytes
SP1 > rP1 > SP2 rw
600
224
0x00E0
0
2 bytes
rP1 > SP2 > rP2
rw
550
225
0x00E1
0
2 bytes
SP2 > rP2 >= 10
rw
540
226
0x00E2
0
2 bytes
10 9999
rw
200
227
0x00E3
0
2 bytes
0 9999
rw
2000
228
0x00E4
0
2 bytes
0 999
rw
250
239
0x00EF
0
1...32 bytes
rw
***
40
0x0028
0
4 bytes
ro
Copy of currently active process data input
41
0x0029
0
2 bytes
ro
Copy of currently active process data output
64
0x0040
1
2 bytes
ro
Actual vacuum value
64
0x0040
2
2 bytes
ro
Lowest measured vacuum value since power up
64
0x0040
3
2 bytes
ro
Highest measured vacuum value since power up
65
0x0041
1
2 bytes
ro
Actual pressure value (unit: 1 mbar)
65
0x0041
2
2 bytes
ro
Lowest measured pressure value since power up
65
0x0041
3
2 bytes
ro
Highest measured pressure value since power up
66
0x0042
1
2 bytes
ro
Supply voltage (unit: 0.1 Volt)
66
0x0042
2
2 bytes
ro
Lowest measured supply voltage since power up
66
0x0042
3
2 bytes
ro
Highest measured supply voltage since power up
148
0x0094
0
2 bytes
ro
Time from start of suction to SP2 (unit: 1 ms)
149
0x0095
0
2 bytes
ro
Time from SP2 to SP1 (unit: 1 ms)
160
0x00A0
0
2 bytes
ro
Leakage of last suction cycle (unit: 1 mbar/sec)
161
0x00A1
0
2 bytes
ro
Last measured free flow vacuum (unit: 1 mbar)
164
0x00A4
0
2 bytes
ro
Maximum vacuum value of last suction cycle
165
0x00A5
0
2 bytes
ro
Minimum input pressure during suction phase of last cycle
564
0x0234
0
1 byte
ro
0x00 = SIO mode
0x10 = IO Link revision 1.0 (set by master)
0x11 = IO Link revision 1.1 (set by master)
140
0x008C
0
cc1
4 bytes
ro
Not erasable (stored every 1000 counts)
141
0x008D
0
cc2
4 bytes
ro
Not erasable (stored every 1000 counts)
142
0x008E
0
cc3
4 bytes
ro
Not erasable (stored every 1000 counts)
143
0x008F
0
ct1
4 bytes
ro
Can be reset by System Command "Reset erasable counters" (stored every 1000
counts)
144
0x0090
0
ct2
4 bytes
ro
Can be reset by System Command "Reset erasable counters" (stored every 1000
counts)
145
0x0091
0
ct3
4 bytes
ro
Can be reset by System Command "Reset erasable counters" (stored every 1000
counts)
Process Data
Erasable condition monitoring counter
Min. pressure during last cycle
Switch Point 1
Reset Point 1
Vacuum on counter
Switch Point 2
Profile name
Disable continuous suction
Eco Mode
Blow off mode
Display Rotation
Display Unit
Profile P 3
(selected by PD Out 0 Profile Set = 3)
Switch Point 1
Reset Point 1
Reset Point 2
Duration automatic blow
Permissible evacuation time
Profile name
Air saving function
Process Settings
Process Data In Copy
Permissible evacuation time
Switch Point 1
Air saving function
Reset Point 1
Disable continuous suction
Duration automatic blow
Permissible evacuation time
Permissible leakage rate
Permissible leakage rate
Duration automatic blow
Permissible leakage rate
Production Setup Profile P1
Process Data Out Copy
Air saving function
Permissible evacuation time
Profile name
Profile name
Disable continuous suction
Output filter
Vacuum Value LO
Vacuum Value HI
Condition monitoring counter
Permissible leakage rate
Switch Point 2
Disable continuous suction
Switch Point 2
Production Setup Profile P0
Initial Settings
Reset Point 2
Profile P 1
(selected by PD Out 0 Profile Set = 1)
Production Setup Profile P3
Profile P 2
(selected by PD Out 0 Profile Set = 2)
Switch Point 1
Reset Point 1
Switch Point 2
Reset Point 2
Production Setup Profile P2
Air saving function
Duration automatic blow
Number of active profile
Erasable valve operating counter
Communication Mode
Free flow vacuum
Pressure Value HI
Supply Voltage
Supply Voltage LO
Evacuation time t
0
Evacuation time t
1
Leakage rate
Valve operating counter
Output 2 function
Signal Type
Observation
Pressure Value
Communication Mode
Erasable vacuum on counter
Counters
Max. reached vacuum in last cycle
Reset Point 2
Pressure Value LO
Supply Voltage HI
Vacuum Value
Monitoring
J. Schmalz GmbH
2 of 3
SCPMi Data Dictionary