Appendix
62 / 68
EN-US · 30.30.01.01961 · 00 · 06/19
17 Appendix
See also
2
SCPMi Data Dictionary 21.10.01.00125_00.pdf [
17.1 Overview of Display Codes
Display
code
Parameter
Note
5P1
Switching point 1
Switch-off value for air-saving function/control
rP1
Reset point 1
Reset value 1 for the control function
5P2
Switching point 2
Activation value of “Parts control” signal output
rP2
Reset point 2
Reset value 2 for the “Parts control” signal
tbL
Blow off time
Set the blow-off time for time-controlled blow-off
CAL
Zero-point adjustment
Calibrate the vacuum sensor
EF
Extended functions
Open the “Extended Functions” submenu
1mF
Information
Open the “Information” submenu
cc1
Total counter 1
Counter for suction cycles (suction signal input)
cc2
Total counter 2
Counter for valve switching frequency
cc3
Total counter 3
Counter for condition monitoring events
Ct1
Counter 1
Erasable counter for suction cycles ("Suction" signal input)
Ct2
Counter 2
Erasable counter for valve switching frequency
Ct3
Counter 3
Erasable counter for condition monitoring events
rct
Erase counters
Erases counters ct1, ct2 and ct3
5oc
Software function
Displays the current software version
5nr
Serial number
Displays the serial number of the ejector
Art
Part number
Displays the part number of the ejector
uni
Vacuum unit
Vacuum unit in which the measurement and setting values are dis-
played
bAr
Vacuum level in mbar
The displayed vacuum is shown in mbar.
P5i
Vacuum level in psi
The displayed vacuum level is shown in psi.
-iX
Vacuum level in inHg
The displayed vacuum is shown in inches of Hg.
k
PA
Vacuum level in kPa
The displayed vacuum level is shown in kPa.
t-1
Max. permissible evac-
uation time
Set the maximum permitted evacuation time
-L-
Max. permissible leak-
age
Set the maximum permissible leakage in mbar/s
dLY
Switch-off delay
Set the switch-off delay for switching signals SP1 and SP2 (Ou2)
(delay)
Eco
ECO mode
Dim/switch off the display
Ctr
Control
Set the air saving function (control function)
on5
Control function on
with leakage monitor-
ing
Switches on the air saving function with leakage monitoring
dc5
Deactivate auto. con-
trol shutoff
Suppresses the automatic valve protection function when set to
YE5
.