Operation Instructions
32 / 42
EN-US · 30.30.01.02533 · 00 · 11/20
1. Press
or
button at "Function Selec-
tion Mode" to display [
F-92
] [
inp
].
2. Press
button to switch to "External Input
Selection".
3. Press
or
button to select external in-
put function.
Accumulated flow external reset = [
r
_
r
]
Auto-shift = [
r
_
a
]
Auto-shift zero = [
r
_
0
]
NOTE:
1. This function is not available with Output
Specification -02 and -04.
2. When external signal is input, the instanta-
neous flow rate value will be shown [
oooo
].
4. Press
button to return to "Function Selec-
tion Mode".
6.14 Fine Adjustment Setting
[
F-94
] This function is to fine adjust flow and pressure display values. Display values can be calibrated
to within ±2.5% R.D.
1. Fine adjustment of instantaneous flow value
1. Press
or
button at "Function Selec-
tion Mode" to display [
F-94
] [
fine
].
2. Press
button to switch to "Fine Adjustment
Setting".
3. Press
or
button to select fine adjust-
ment OFF or to set fine adjustment instanta-
neous flow rate value or pressure value.
Fine adjustment function off = [
off
]
Fine adjustment of pressure value = [
pre5
]
Fine adjustment of Instantaneous flow rate
value = [
]
ð
is displayed.
4. Press
button to select "Fine adjustment of
Instantaneous flow rate value".
ð
Display changes to [value] / [
F5t
] respec-
tively
[
0.00
] Flashing Alternately
5. Press
or
button to set fine adjust-
ment value (left display).
NOTE: Right display will flashing between
[
0.00
] and [
f5t
].