Operation Instructions
EN-US · 30.30.01.02533 · 00 · 11/20
29 / 42
6.7 Unit Selection
[
F-06
] Select the flow unit and pressure unit of the sensor.
1. Press
or
button at "Function Selec-
tion Mode" to display [
F-06
] [
vnit
].
2. Press
button to switch to "Flow Unit Selec-
tion".
3. Press
or
button to select flow unit.
2 flow unit selections include:
LPM(L/min), CFM(ft
3
/min*10
-2
)
NOTE: When the measured flow rate range is
500mL/min or 10OOmL/min, the unit of LPM is
selected to represent the unit in mL/min.
4. Press
button to switch to "Pressure Unit
Selection".
5. Press
or
button to select pressure
unit.
4 pressure unit selections include:
kPa, kgf/cm
2
, bar, psi
6. Press
button to return to "Function Selec-
tion Mode".
6.8 Flow Reference Standard Selection
[
F-07
] Select the flow value is shown under standard or normal condition.
1. Press
or
button at "Function Selec-
tion Mode" to display [
F-07
] [
refe
].
2. Press
button to switch to "Flow Reference
Standard Selection"
3. Press
or
button to select the stan-
dard or normal condition.
Standard conditon (ANR) = [
Anr
]
Normal condition (NOR) = [
nor
]
NOTE:
1. Stardard condition (ANR): the display value
is calculated under 20°C, 1atm.
2. Normal condition (NOR): the display value is
calculated under 0°C, 1atm.
3. Flow rate in the specification is the value at
standard condition (ANR).
4. Press
button to return to "Function Selec-
tion Mode".