4.9
Pump Kit Installation
4.10
Connection to the pool
fig. 19
R
Pipework
S
Hexagon screws
V
Adaptor
Mount the pump free of all tension with
the hexagon screws M8 (S) on the base
frame.
Warning!
1. Do not use any vibration dampers
between the pump and the base frame.
2. If the pipework (R) to the pump is longer
than 6 m then the nominal width must
be increased.
- Suction side from DN 65 to a min.
of DN 80
- Pressure side from DN 50 to a min.
of DN 65.
3. Then always mount the adaptors (V) on
the pump body.
fig. 20
14
Return connection
17
Suction connection
20 / 91 / 92
Installation kit
Stick the adaptors (14+17) to the pipe
connection on the installation kit (20/91/
92). Alternatively, by using pipework,
stick to the pump-side end of the
pipework.
Warning!
Always be sure to lay the pipework using
bends and not angles to keep the pipe
resistance to a minimum.
8226