![Schletter FixGrid18-100 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/schletter/fixgrid18-100/fixgrid18-100_mounting-instructions_1212726007.webp)
APPLY THE FIRST MODULE
INSTALL THE
FIRST MODULE
INSTALL
FIRST MODULE
•
Click Rapid 16 end clamps into place at the edge of the module field and
position them. Also click the Rapid 16 middle clamp into place at a generous
distance so that the module can be inserted between the clamps.
•
Place the module on the FixZ System Rail 18 and align it with the upper edge
using the pre-attached Rapid 16 clamps. Pay attention to the alignment of
the module row.
•
Apply the Rapid 16 end clamps (at the top and at the bottom) to the module
and tighten, Screws M8 (T40).
•
Place the module center clamp on the module; do
not
tighten.
•
Connect the module cable according to the plan.
•
Apply the next module.
•
Tighten the middle clamps (at the bottom and at the top) between the
modules with Screws M8 (T40)
•
Pre-assemble the other middle clamp on the free module side.
•
Connect the module cable according to the plan.
•
Repeat steps up to the last module in the row.