                                                               EDI 

- V5 CONTROL 

 

EDI-V5_Install 1/11/2011 

  

 

  

  

 
 
 
 
 
 

 

 

 

For EDI-V5 Controls Using The Inverter Drive 

• 

Wiring The Control 

• 

Configuring The Control 

• 

Customizing The Display 

• 

Access Code Description 

• 

How To Use The Option Codes 

• 

Screen Alerts And Alarms

 

• 

EDI-V5 Accessories

 

 

 
 

For Controls with firmware revision EDI-V5.100.5 and earlier. 

 

EDI-V5 CONTROL 

INSTALLATION MANUAL 

WIRING and SETUP INSTRUCTIONS 

Содержание EDI-V5 CONTROL

Страница 1: ...rter Drive Wiring The Control Configuring The Control Customizing The Display Access Code Description How To Use The Option Codes Screen Alerts And Alarms EDI V5 Accessories For Controls with firmware...

Страница 2: ...to improper operation equipment damage or serious injury or death The EDI control should only be installed and wired by experienced electricians Make sure the wiring meets all applicable regulations...

Страница 3: ...spout Figure 1 shows the field wiring required for the 110 volt supply sensor and motor connections Wire these using the following 3 step procedure Panel Power 110 Volt Wiring Motor Power 230 Volt Wi...

Страница 4: ...sors Refer to Figure 1 and 3 and route the 4 sensor wires into the upper left section of the control box as shown Connect the 4 sensor wires to the screws labeled 1 2 4 and 5 on the barrier relay as s...

Страница 5: ...de cluster on the codewheel passes by See the diagram on the previous page for the location of the switches that manually operate the motor Manually press the Fwd or Rev buttons to begin spout motion...

Страница 6: ...te Some of the information on the sample screens shown may be different than your screen depending on the type of the distributor being installed Upon Power up or Reset the control will display the fo...

Страница 7: ...lm 0 SCHLAGEL INC 002 POSITION 2 _ FLATBACK SWINGSET V5 001 10 DUCTS Dir 0 Slt 5 W 2 27 Upon completion of the Autotune process an information screen will appear with the information it has acquired B...

Страница 8: ...SCHLAGEL INC SCHLAGEL INC EDI V5 CONTROL Page 8...

Страница 9: ...ght These changes are made using special 4 digit access codes The following changes were made to the default OPERATING screen Line 1 The caption on this line has been changed from SCHLAGEL INC to RECE...

Страница 10: ...to 16 characters may be entered A space is entered with a single Shift and Space A backspace can be executed by a double Shift and Space When finished press the Enter key The display will return to th...

Страница 11: ...ers may be entered When finished press the Enter key The display will return to the OPERATING screen showing the new information Hint The position of the distributor can always be moved to the desired...

Страница 12: ...on adjustment numbers for any duct This number will then be used for all spout positions 5993 Define Duct Data Assign Access numbers Function numbers and Names for any duct 5994 Erase Memory Erase all...

Страница 13: ...he screen above it is shown as being off To turn it on press 16 Enter The following screen then appears showing the present status of this option and requests a 0 or 1 input to change it or Enter to l...

Страница 14: ...ete c 0 Off 1 On b 0 6 I O Binary c 0 Off 1 On b 0 7 I O Network d 0 Off 1 On b 0 8 N A 0 9 Auto Mode Speed 0 1 Sec 1 4 Sec 0 10 N A Options 0 11 Simulator Mode 0 Off 1 On 0 12 10 Second Timeout 0 Off...

Страница 15: ...hanical difficulty preventing proper final positioning Remedy This is not a fatal error but the alarm will stay in the screen until a successful position has been achieved To clear the alarm re enter...

Страница 16: ...e module One UCOM is used on each EDI control that will connect to a UIO interface module Remote Keypad Display Kit Remote keypad displays allow operation of an EDI control from multiple locations The...