background image

2

WPR400 Wireless Portable Reader User Guide

CONTENTS

Overview ........................................................................................................................................ 3

Getting Started .............................................................................................................................. 3

WPR400 Operation ....................................................................................................................... 4

WPR400 Range ........................................................................................................................ 4
Connecting a Reader to the WPR400 (if necessary)................................................................. 4
Permanently or Temporarily Mount the WPR400....................................................................... 5

Schlage Utility Software (SUS) ...................................................................................................... 6

Coupling with the SUS .............................................................................................................. 6

Link to a PIM400 (Reader mode only) ........................................................................................... 7

Re-link The WPR400 ..................................................................................................................... 7

Change the RF Channel ................................................................................................................ 8

Enable Dynamic Channel Switching .............................................................................................. 8

Reset To Factory Defaults.............................................................................................................. 9

WPR400 LED Reference ............................................................................................................... 9

Link Mode LED Reference ........................................................................................................ 9
Normal Operation LED Reference............................................................................................. 9

Test Mode .................................................................................................................................... 10

Link to the PIM400-TD2 in Test Mode ..................................................................................... 11
Use the WPR400 in Test Mode ................................................................................................ 12
WPR400 Test Mode LED Reference ....................................................................................... 12
Improve RF Communication .................................................................................................... 12

Batteries ...................................................................................................................................... 13

Charge Batteries ..................................................................................................................... 13
Install or Replace Batteries ..................................................................................................... 13

Troubleshooting ........................................................................................................................... 14

FCC/IC Statements ..................................................................................................................... 15

www.schlage.com/support

877.671.7011

Содержание WPR400

Страница 1: ...P516 098 WIRELESS PORTABLE READER WPR INSTRUCTIONS FOR WPR400 Para el idioma español navegue hacia www schlage com support Pour la portion française veuillez consulter le site www schlage com support ...

Страница 2: ...r mode only 7 Re link The WPR400 7 Change the RF Channel 8 Enable Dynamic Channel Switching 8 Reset To Factory Defaults 9 WPR400 LED Reference 9 Link Mode LED Reference 9 Normal Operation LED Reference 9 Test Mode 10 Link to the PIM400 TD2 in Test Mode 11 Use the WPR400 in Test Mode 12 WPR400 Test Mode LED Reference 12 Improve RF Communication 12 Batteries 13 Charge Batteries 13 Install or Replace...

Страница 3: ...ader In Test mode the WPR400 continually tests the quality of the RF link with a PIM400 The WPR400 is shipped in reader mode See Test Mode on page 10 for information on using the WRP400 as a tester If ordered as WPR400 x DT the unit is shipped in Test mode LED Indicators Schlage Button On Off Switch Power Jack GETTING STARTED Follow these steps when setting up a WPR400 1 Install the PIM400 Refer t...

Страница 4: ...M400 and WPR400 is 200 feet 61 meters horizontally on the same floor in a building with normal construction materials For a line of sight installation maximum distance is 1000 feet 305 meters Connecting a Reader to the WPR400 if necessary 1 Connect the reader cable to the reader as shown below 2 Secure the reader to the front cover using the screws and washers provided 1 Reader cable Reader 2 ...

Страница 5: ...Using the base as a template mark the mounting holes 3 Drill a hole at each mark and use a wall anchor and screws not provided to attach the WPR400 4 If mounted on a metallic surface use one inch non metallic spacers not provided Temporary mount with Velcro strips 1 Attach adhesive Velcro strips hook side to the WPR400 s base 2 Attach the other adhesive Velcro strips loop side to the mounting surf...

Страница 6: ...lage button blinks alternate right left red and the SUS display indicates WPR400 at the bottom of the main screen 7 The SUS software is now available to view or edit credential reader settings or update firmware To Edit Settings or Update Firmware on the WPR400 the SUS software and the WPR400 must be coupled Follow the steps below to couple the WPR400 and the SUS Coupling with the SUS 1 With power...

Страница 7: ...RF channel number 6 If the link fails the WPR400 Schlage button will blink red three 3 times and five 5 short beeps will sound The PIM400 will remain in link mode so the link may be attempted again The WPR400 will fail to link if the PIM400 is not properly set to link mode The LEDs on the PIM400 will alternately blink red and green The WPR400 will fail to link if it is not in RF range of the PIM40...

Страница 8: ...ect a Door Address and click on the Link button 10 Try to link again using the new RF channel ENABLE DYNAMIC CHANNEL SWITCHING Activation of Dynamic Channel Switching will terminate links with other WAPMs previously linked to the PIM400 Dynamic Channel Switching DCS is controlled by the PIM400 the WPR400 is linked with DCS may be enabled on the PIM400 through the Schlage Utility Software SUS Follo...

Страница 9: ...ault reset repeat steps 2 through 4 above within 10 seconds of the confirmation signals of Level 1 factory default reset If more than 10 seconds pass after the confirmation signals of Level 1 reset then Level 1 reset will be repeated WPR400 LED REFERENCE Link Mode LED Reference Schlage LEDs Beeps Action 1 Red 1 Green 0 One link request was sent to find a PIM400 in link mode This action will repeat...

Страница 10: ...and remove the WPR400 cover 2 Place a jumper across the two pins of the Mode connector on the main circuit board Jumper TEST MODE LINK MODE Jumper Jumper 3 Reassemble the WPR400 before powering on When powered on the WPR400 will automatically enter Test mode and test the quality of the RF link If the RF link fails the Schlage button will blink red three 3 times and five 5 short beeps will sound Re...

Страница 11: ...0 TD2 3 Connect the bare leads from the power supply to J2 DC Power screw terminal on the PIM400 TD2 4 Connect the power supply to 120 VAC 5 Press and release LINK 1 switch SW2 to link Access Point 1 or LINK 2 switch SW3 to link Access Point 2 6 The corresponding LED LED1 for LINK1 LED2 for LINK2 blinks red and green This indicates that the PIM400 TD2 is in Link Mode To abort Link Mode press the s...

Страница 12: ...mplete see Batteries on page 13 A successful transmission rate greater than 85 is needed for a successful link and to ensure that more than 99 6 of all RF transmissions will be completed error free If the RF transmission is poor or unsuccessful attempt modifications to improve the transmission See Improve RF Communications below Improve RF Communication 1 Ensure that the distance between the PIM40...

Страница 13: ...ry 1 Open the power jack cover 2 Plug the battery charger in to the power jack 3 Connect the battery charger to 120 VAC Full battery charge will take approximately 4 8 hours Install or Replace Batteries 1 Remove the WPR400 cover 2 Disconnect the battery pack 3 Remove the battery retainer and the old battery pack 1 2 3 ...

Страница 14: ...ry pack in the same location as the old battery pack 5 Carefully pack the battery wires and reattach the battery retainer 6 Connect the new battery pack 7 Reattach the WPR400 cover making sure no wires are pinched 4 5 6 7 TROUBLESHOOTING For troubleshooting browse to www schlage com support ...

Страница 15: ...armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communication However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televis...

Страница 16: ... 2011 Ingersoll Rand Company Printed in U S A P516 098 Rev 10 11 c ...

Отзывы: