Specifications

• 

Power 120 VAC, 60 Hz

• 

Signal (Frequency) 908.42 MHz

Software Fuse

The RP200 is designed to protect itself against loads that exceed it’s maximum power rating. The application of a load that 
exceeds that rating is quickly sensed by the dimmer and it responds by immediately shutting off all power to that load. If 
the dimmer doesn’t seem to work, or if it only works momentarily, check to see that the total light wattage doesn’t exceed 
the 300W rating of the RP200. If a properly sized load is restored to the dimmer, it can be operated normally once again.

Over-current protection

The RP200 hardware has an over current detection circuit, which is final protection against overload. If the software 
fuse should fail to shut down the dimmer when overloaded, backup protection is provided by an internal fuse. This fuse 
is not user serviceable. Check your home circuit breakers before concluding that the product must be returned to the 
manufacturer for repair at a nominal charge.

FCC NOTICE

Note: This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following measures:
• 

Reorient or relocate the receiving antenna.•

• 

Increase the separation between the equipment and receiver.•

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.•

• 

Consult the dealer or an experienced radio/TV technician for help.•

IC NOTICE

This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du 
Canada.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must 
accept any interference, including interference that may cause undesired operation of the device.

About RP200’s Certification

In addition to compliance with product safety standards, the RP200 is also certified to comply with 
applicable FCC and IC rules and regulations governing RF and EMI emissions.