background image

3

Basic Access Control Using an Electric Door Strike

1. 

Connect the red (V+) and black (V-) wires to your power supply.

2. 

Connect the blue wire (relay common) to positive on your power supply.

3. 

Connect the brown wire (relay normally open) to the positive connection on your door strike.

4. 

Connect negative connection on your door strike to the negative on the power supply.

Shunting a Normally Closed Zone

1. 

Connect the red (V+) and black (V-) wires to your power supply.

2. 

Connect the blue wire (relay common) to the common connection on the alarm contacts.

3. 

Connect the brown wire (relay normally open) to the normally open connection on the alarm contacts.

Содержание KP212

Страница 1: ...ounting Dimly Lit Areas Description Schlage s KP212 keypad combines elegant looks with a mullion mount design in a rugged vandal resistant case which you can use for almost any application The KP212 has hardened backlit keys designed to perform in medium to high traffic areas and in rough duty environments The electronics are also conformal coated which makes the keypad suitable for indoor or outd...

Страница 2: ...pad onto the mounting surface using the provided screws Do no over tighten the screws which may result in damage Keypad Mounting Height Mounting height can vary depending on requirements An appropriate range is typically between 48 and 52 inches on center off the floor 48 52 Wiring an Electromagnetic Lock Maglock 1 Connect the red V and black V wires to your power supply 2 Connect the blue wire re...

Страница 3: ...mally open to the positive connection on your door strike 4 Connect negative connection on your door strike to the negative on the power supply Shunting a Normally Closed Zone 1 Connect the red V and black V wires to your power supply 2 Connect the blue wire relay common to the common connection on the alarm contacts 3 Connect the brown wire relay normally open to the normally open connection on t...

Страница 4: ...the negative on your power supply 3 Connect the white black wire to the normally open connection on the REX device Wiring the Bell Output to a Speaker The KP212 keypad has a built in bell button which triggers a relay output when pressed This relay is normally open and the contact closes when triggered You can use this relay output to trigger devices that require a momentary closure such as a door...

Страница 5: ...ode Command 30 Set Clear Keypad Options options below defaults in bold 30 option set clear Option Clear Set 0 Audio Keypress Feedback 0 Disabled 1 Enabled 1 Visual Keypress Feedback 0 Disabled 1 Enabled 2 Auto Entry 0 Disabled 1 Enabled 3 Keypad Illumination 0 Disabled 1 Enabled 4 Keypad Dimming 0 Disabled always bright 1 Enabled 5 Door Bell Select 0 Disabled 1 Enabled Command 32 Set Bell Output T...

Страница 6: ...e following example shows how to program user 2 with a code of 1749 and user 3 with 9328 The master code is 4875 1 Enter Program Mode 99 4875 2 Program User 2 2 1749 code 3 Program User 3 3 9328 code 4 Exit Program Mode Programming a Toggle User The following example shows how to program user 4 as a toggle user with a code of 98773 The master code is 4875 1 Enter Program Mode 99 4875 2 Change the ...

Страница 7: ...support department at 1 800 343 9502 outside MA or 1 800 733 9502 inside MA Testing the Keypad After installing the keypad IEI recommends that you perform the keypad self test once a year to ensure that the keypad is working properly To perform the self test with the unit powered up press the following keys on the keypad 7890 123456 If all 12 key presses are accepted the keypad enters self test mo...

Страница 8: ...0 Rev 04 11 a Keypad Mounting Template Mounting Holes Wiring Hole 3 3 393 1 1 433 The Schlage keypad is desingd for surface mount applications You must drill a hole for the wire harness connector as shown so the unit is flat against the mounting surface ...

Отзывы: