Programming the KP212 Keypad
To program the KP212 you fi rst must enter program mode. To enter program mode enter the following on the keypad:
99 # program code
(default program code is 1234).
Keypad Default Settings
Option
Default Setting
Option
Default Setting
Master Code
1234
Main Relay Time
5 Seconds
Audio Keypress Feedback
Enabled
Visual Keypress Feedback
Enabled
Auto-Entry
Disabled
Door Bell Select
Continuous
Keypad Illumination
Enabled
Keypad Dimming
Enabled
Programming Options Chart
Command/Action
Keys to Enter/Details
Change Master Code
1 # new code
new code
Change Main Relay Time
relay time # 1 # master code
master code
Add/Change User
user location # new code
new code
Note: Users programmed with this command use master code relay time.
Add Toggle User
00 # user location # new code
new code
Add User with Specifi c Relay Time
relay time # user location # new code
new code
Command 30
Set/Clear Keypad Options (options below,
defaults in bold)
30 # option # set/clear # **
Option
Clear
Set
0 – Audio Keypress Feedback
0 = Disabled
1 = Enabled
1 – Visual Keypress Feedback
0 = Disabled
1 = Enabled
2 – Auto-Entry
0 = Disabled
1 = Enabled
3 – Keypad Illumination
0 = Disabled
1 = Enabled
4 – Keypad Dimming
0 = Disabled (always bright)
1 = Enabled
5 – Door Bell Select
0 = Disabled
1 = Enabled
Command 32
Set Bell Output Time
32 # 0 # time #
Set timed output (1 – 99 seconds)
32 # 0 # 0 #
Set to continuous
Command 46
Reset Keypad to Default Settings
46 # 00000 # 00000 #
Exit Program Mode
Press the
Key
Notes:
1.
The KP212 can store 120 user codes, including the master code. Codes can be from 1 to 6 digits long.
2.
When auto-entry is enabled, users with codes the same length as the master code do not have to press the
key after entering
their code to enter the door.
3.
When keypad dimming is disabled the backlighting remains at full intensity (does not dim).
4.
When the door bell output is set to continuous the relay is energized as long the door button is pressed. When you release the
button the relay de-energizes.