background image

20-Zone, and 48-Zone LED Keypads V1.3

(DGP-620/648)

Programming Guide

M

ODULE

 P

ROGRAMMING

 M

ODE

The keypad, like all other modules in the Digiplex system, is
programmed through the control panel. To enter the Module
Programming Mode:

P

ROGRAMMING

 G

UIDE

Serial Number: ___/___/___/___/___/___/___/___

Location:______________________________________________

Bold = 

Default Settings

Bold

 = Default Setting

Section:

[006]

 ___/___/___

PGM Timer 000 to 255 (refer to the 

Digiplex LED Keypad Installer

Manual

).

[007]

 ___/___ (  

1  2  3  4  5  6  7  8 

PGM Activation Event 
For the PGM Table refer to the 

Digiplex Programming Guide

.

[008]

 ___/___ (  

1  2  3  4  5  6  7  8 

PGM Deactivation Event 
For the PGM Table refer to the 

Digiplex Programming Guide

.

[009]

 Zone Display 

(DGP-620 only)

20 - Zone Keypad: 

[0] = 1 to 20    

[1] 

= 21 to 40

Step 1: Press and hold the [0] key.
Step 2: Enter the [

INSTALLER

 

CODE

] (by default 000000).

Step 3: Enter section [953].
Step 4: Enter the keypad’s 8-digit [

SERIAL

 

NUMBER

].

Step 5: Enter the 3-digit [

SECTION

] to program.

Step 6: Enter the required [

DATA

].

SECTION [001]: Partitioning

Option

OFF

ON

[1]

Partition 1

 l

 Disabled

 l

 

Enabled

[2]

Partition 2

 l

 Disabled

 l

 

Enabled

[3]

Partition 3

 l

 Disabled

 l

 

Enabled

[4]

Partition 4

 l

 Disabled

 l

 

Enabled

[5]

Not used

 l

 N/A

 l

 N/A

[6]

Not used

 l

 N/A

 l

 N/A

[7]

Not used

 l

 N/A

 l

 N/A

[8]

Not used

 l

 N/A

 l

 N/A

SECTION [002]: General Options

Option

OFF

ON

[1]

Not used

 l

 N/A

 l

 N/A

[2]

Not used

 l

 N/A

 l

 N/A

[3]

Not used

 l

 N/A

 l

 N/A

[4]

Confidential Mode

 l

 

Disabled

 l

 Enabled

[5]

To Normal Mode
(if 

[4]

 is enabled)

 l

 

Enter

Code

 l

 Press

Button

[6]

Not used

 l

 N/A

 l

 N/A

[7]

Not used

 l

 N/A

 l

 N/A

[8]

Not used

 l

 N/A

 l

 N/A

SECTION [003]: General Options

Option

OFF

ON

[1]

Muting

 l

 

Disabled

 l

 Enabled

[2]

Exit Delay Beep

 l

 Disabled

 l

 

Enabled

[3]

Not used

 l

 N/A

 l

 N/A

[4]

Chime on Zone Closure

 l

 

Disabled

 l

 Enabled

[5]

Not used

 l

 N/A

 l

 N/A

[6]

Not used

 l

 N/A

 l

 N/A

[7]

Not used

 l

 N/A

 l

 N/A

[8]

Not used

 l

 N/A

 l

 N/A

SECTION [004]: Beep on Trouble

Option

OFF

ON

[1]

System & Clock Loss

 l

 

Disabled

 l

 Enabled

[2]

Communicator

 l

 

Disabled

 l

 Enabled

[3]

Modules & Bus

 l

 

Disabled

 l

 Enabled

[4]

All Zones Troubles

 l

 

Disabled

 l

 Enabled

[5]

Not used

 l

 N/A

 l

 N/A

[6]

Not used

 l

 N/A

 l

 N/A

[7]

Not used

 l

 N/A

 l

 N/A

[8]

Not used

 l

 N/A

 l

 N/A

SECTION [005]: General Options

Option

OFF

ON

[1]

PGM State

 l

 

Normal

 

Open

 l

 Normally

Closed

[2]

PGM Timed Mode

 l

 

Disabled

 l

 Enabled

[3]

PGM Base Time

 l

 

1

 

Second

 l

 1 Minute

[4]

PGM Override

 l

 

Disabled

 l

 Enabled

[5]

Keypad Tamper

 l

 

Disabled

 l

 Enabled

[6]

Not used

 l

 N/A

 l

 N/A

[7]

Not used

 l

 N/A

 l

 N/A

[8]

Not used

 l

 N/A

 l

 N/A

Отзывы: