PARTITION KEYPAD 

 

CA-64 S

 

 

 

ca64s_e 06/04 

The CA-64 S partition keypad is a device designed to work with the CA-64 alarm control panel. 
It is used for arming and disarming a single partition, it is provided with the access control 
feature, as well as it controls the operation of electromagnetic door lock and monitors whether 
the door is open or locked. The partition keypad allows changing the user code and calling the 
functions for control external devices. has been written for the module software version 1.10, 
control panel software version 1.04.01, and DLOAD64 program version 1.04.02. 

DESCRIPTION OF MODULE  

 
 

 
 
 

 
 
 
 
 
 

 

 
 

Figure 1 

Partition keypad is provided with 12 keys with permanent or temporary backlit (operating 
automatically), and three LEDs described as follows:  

  ALARM (red) – continuous light indicates an alarm triggered in the partition operated with 

this partition keypad, and LED flashing indicates that alarm occurred in this partition 
previously.  

  ARMED (green) - continuous light informs that the partition assigned to this partition 

keypad is armed. The LED blinks when the delay time is counted down.  

  TROUBLE (yellow) – the LED blinks when technical problem has been detected in the 

system. Check LCD keypad for a kind of trouble. Indication of this LED relates to the entire 
system, not only the partition operated with this partition keypad. When this partition is 
armed, the LED goes off, and disarming causes the LED to start indicating again.  

The way of partition keypad operation depends in large degree on the software installed by the 
installer. The description of situation, for which the way of partition keypad operation depends 
on the program installed, is marked with the text in brackets: (service setting).   

USER FUNCTIONS  

The partition keypad controls and operates the partition in the alarm system, to which it was 
assigned by the installer, and includes entering the USER CODE and pressing the key marked 
# or 

9

. Enter the code by pressing from 4 to 8 partition keypad numeric keys one by one.   

Functions accessible from partition keypad:  

>

 

CODE # 

arming / disarming of the partition, alarm cancelling or execution of 
control function.  

ALARM

 

ARMED 

TROUBLE 

1

 

2

 

3

 

6

 

4

 

5

 

7

 

8

 

9

 

0

 

#

 

Содержание CA-64 S

Страница 1: ...ms that the partition assigned to this partition keypad is armed The LED blinks when the delay time is counted down TROUBLE yellow the LED blinks when technical problem has been detected in the system Check LCD keypad for a kind of trouble Indication of this LED relates to the entire system not only the partition operated with this partition keypad When this partition is armed the LED goes off and...

Страница 2: ...ause disarming and operation of the relay only if the partition isn t temporary bypassed and the user has the right to disarm and use this keypad There is a possibility to control various equipment with the control panel for example switching off the lighting starting air conditioning etc The installer should inform the user which equipment may be operated by means of the given keypad Control func...

Страница 3: ... user who enters his code now or end of code validity period Four short beeps and one long beep acceptance of execution of function selected code change done confirmation of a guard round Five short beeps dependent door open the relay has not been activated In order to activate the relay close the dependent door and enter code again Flashing of key lighting may be arranged instead of audible signa...

Страница 4: ...ou start to wire the module to the existing alarm system 1 Remove the plastic module casing by pressing the clips which fix the casing bottom 2 Fix the bottom of plastic casing to the wall The connecting leads should be passed through the rectangular opening in this part of casing 3 Connect the leads of first or second expander bus to the following terminals DTA CLK and COM first bus CK1 DT1 COM s...

Страница 5: ...tion process the control panel saves into memory the special number 16 bits which is used for checking the presence of the module in the system Replacement of the module with another one even if the same address is set without carrying out the identification process again causes alarm module tamper verification error 4 Program the partition keypad functions and define users authorised to use this ...

Страница 6: ...F if door open The relay is active until the door is open input IN is disconnected from ground but no longer than for the Relay ON time Fixed ON time OFF if door closed The relay is active for the duration of door opening input IN disconnected from ground and it is de activated when the door is closed input IN is connected to ground again but the relay is active no longer than the Lock ON time Rel...

Страница 7: ...tition keypad does not trigger an audible alarm but a message is transmitted to the monitoring station only and the input type 12 silent alarm is activated Figure 4 Changing access code When this option is marked the user code change function is accessible Quick arming Arming by pressing the keys 0 and in sequence Control BI output This option allows the partition keypad to accept the code for whi...

Страница 8: ...fter pressing any key à Zone violation key backlit is switched on also when the zone with the number entered in the field next to the option name has been violated à Entry delay part key backlit is also switched on when the entry delay counting down is started in the partition with the number entered in the field next to the option name NOTE Automatic keypad backlit is active for approximately 40 ...

Отзывы: