Keep all safety devices, air vents and the motor
housing free of dirt and dust. Wipe the equipment
with a clean cloth or clean it with compressed air
at low pressure.
•
We recommend that you clean your device after
each use.
•
Clean the unit regularly with a damp cloth and
some soft soap. Do not use cleaning agents or
solvents; they may damage the plastic parts of the
appliance. Make sure that no water can get inside
the unit.
10. Storage
Store unused equipment in a dry, locked place out of
the reach of children.
Note the following to extend the service life of your
air dehumidfier and to ensure a perfect function:
•
Drain the water collecting container and dry it care-
fully.
•
Check the air dehumidifier for perfect condition to
ensure a safe use of it after a longer period of stor-
age.
•
Carefully cover the air dehumidifier.
11.
Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer‘s mains connection as well as
the extension cable used must also comply with
these regulations.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of
-
ten damaged.
This may have the following causes:
•
Passage points, where connection cables are
passed through windows or doors.
•
Kinks where the connection cable has been im-
properly fastened or routed.
•
Places where the connection cables have been cut
due to being driven over.
•
Insulation damage due to being ripped out of the
wall outlet.
•
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H 07 RN“.
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
avoid water sillage The pump will close automati-
cally after forty seconds continuous operation.
3. Use UP and Down key to set
or adjust humidity in the range between 26% and
90%. When the environmental humidity is below
26% “CO” will be displayed.
4. Press the “T” key to view working time and
press the “T”. if you want to view the totally work-
ing time, please press “T” once more, ant it will
shows for 10 seconds and returns automatically to
the original working hours.
5. Defrost Indicator: The unit begins to defrost when
the defrost indicator lights. When defrosting fin-
ishes, the unit begins to dehumidify automatically
again.
6. As to a much wetter space, use a plastic pipe with
diameter larger than 170mm, and tie the pipe to
hood, it will be much faster and more effective to
make it dry.(Fig. 6)
Lock function
If the keys of “T” and “P” are pressed for 2 seconds
at the same time, the operating light will keep shining
and all the keys on the control panel will be in lock,
but it can be unlock by the same action again.
Important Instructions
•
The compressor turns itself on three minutes after
turning on the dehumidifier.
•
The ideal temperature for the dehumidifier to work
in is from about +5°C up to about +35°C
•
When the device defrosts the cooling fan works
properly but the inserted compressor switches it-
self off.
•
It is recommended to clean the filter once a month.
Carefully clean it with clear warm water.
•
Leave a safe distance between wall and air in- and
outlets.
•
Empty the collection container after each use.
•
Unplug the device and attach the mains plug to the
product if it is not in use over a longer period.
•
Don´t tilt the device more than 45°, neither when
moving nor when operating.
•
If the dehumidifier was tilted by accident, don´t use
it for a period of 12 hours.
9. Maintenance
The air dehumidifier is designed for a trouble free op-
eration and a minimum of maintenance. All movable
parts are permanently lubricated. Inside the device,
there are no other parts to be maintained.
Replacing the Battery (Fig 7)
•
Remove the screws in the four corners of the con-
trol panel.
•
Once the screws are removed, carefully lift the con-
trol panel.
•
On the PCB is a 6F22 9V battery. Remove the bat-
tery and replace with new.
•
Refit the control panel onto the PCB
•
Refit the four screws.
Cleaning (Fig 8
•
Using luke-warm water to wash the airfilter.
T