Technical data
Model
DH6500i
Rated power
750 W
Max. power
1080 W
Electrical power supply
230 V / 50 Hz
Rated current
3.3A
Temperature range
5° - 35°C
Humidity of air range
26% - 90%
Dehumidification performance at
(30°C/80%)
65 L/d
Refrigerant
R410a
Refrigerant quantity
560g
Self purging
Yes
Pump power
2.5 L/min
Air flow rate
400 m
3
/h
Room area
80 - 100 m
2
Hose length
5 m
Pump hight
4.5 m
Display
Yes
Weight
38 kg
Subject to technical modifications!
7.
Montage
Attaching wheels and handle Fig.
Put handle into the recesses provided and fix it with
6 screws.
8.
Operation
1. Operate teh dehumidifier in an eclosed area. Close
all doors and windows. Place the dehumidifier
away from walls and furnishings. (Fig.4)
2. The dehumidifier pump connects to a plastic drain-
age hose. Uncoil the entire hose ensuring there are
no kinks or restrictions and place the unattached
end into a water vessel or run to outdoors.The Posi-
tion of drain water pipe would not be too high (until
4.5 m) (Fig.5)
3. Plug in the device
4. Press teh ON/OFF key to turn the unit on, it will get
into working moede automatically.
5. Set the humidity as described.
6. After using, press ON/OFF key to turn the unit off,
while water pump will turn on automatically for 40
seconds to drain the rest water, ant turn off auto-
matically.
7. As to a much wetter space, use a plastic pipe with
diameter larger than 170mm, and tie the pipe to
hood, it will be much faster and more effective to
make it dry.
Functions of Keys:
1. Press teh ON/OFF key to turn the unit On
or Off
2. Press teh PURGE key to emty water from
the pump reservoir. During normal operation the
pump purges automatically when the reservoir is
full. Use PURGE before moving the machine to
use of the appliance in a safe way and under-
stand the hazards involved. Children shall not
play with the appliance. Cleaning and user main-
tenance shall not be made by children without
supervision.
19. Drain the water container before transporting the
device to prevent spills.
20. Unplug the device if problems like smell of burn-
ing occur while using it.
SAFETY INFORMATIONS SERVICE/ MAINTE
-
NANCE
1.
Only original parts may be used for maintenance
and accessories.
2.
Before using, always visually inspect to see that
the tools are not worn or damaged. Replace
worn or damaged elements and bolts. Keep all
nuts, bolts and screws tight to be sure the equip-
ment is in safe working condition.
m
WARNING!
Improper maintenance or ignoring/ not rectifying a
problem during the operation may become a source
of danger. Operate your machine only if regular-
ly maintained. Only in this way you can assume that
your device is operating safe, economical and with-
out malfunctions.
Do not clean, maintain, setup or repair the ma
-
chine whilst running. Moving parts may cause
serious injuries.
Do not use fuel or other flammable solvents to clean
the equipment.
Repairs must be carried out by qualified experts with
appropriate knowledge about the product.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly quali-
fied persons in order to avoid a hazard.
RESIDUAL RISKS
Even if used properly, residual risks can exist even if
the relevant safety regulations are complied with due
to the design determined by the intended purpose.
Residual risks can be minimised if the “Safety ad-
vices” and the “Intended usage” as well as the whole
of the operating instructions are observed. Observing
these instructions, and taking proper care, will reduce
the risk of personal injury or damage to the equip-
ment.
•
Risk from electricity when using improper electrical
connections.
•
Touching live parts of opened electrical compo-
nents.
In addition, in spite of all t he precautionary measures